Input Chart Natural Gas
Model
Description
Controls
BTU/HR
kW/HR
G24-24G
G24-24GTHX
24” (610mm)
Griddle
2 Hi-lo Valves
2 Thermostats
66,500
60,000
19.48
17.58
G24-36G
G24-36GTHX
36” (914mm)
Griddle
3 Hi-lo Valves
3 Thermostats
100,000
90,000
29.31
26.38
G24-48G
G24-48GTHX
48” (1219mm)
Griddle
4 Hi-lo Valves
4 Thermostats
133,000
120,000
38.98
35.17
G24-60G
G24-60GTHX
60” (1524mm)
Griddle
5 Hi-lo Valves
5 Thermostats
166,500
150,000
48.78
43.96
G24-72G
G24-72GTHX
72” (1829mm)
Griddle
6 Hi-lo Valves
6 Thermostats
200,000
180,000
58.61
52.75
Installation Notes
Manifold Operating Pressure
Combustible Wall Clearances: In (mm)
Ratings shown are for natural gas
installations up to 2000 feet (610m)
above sea level. BTU input ratings
must be de-rated for high altitude
installations. Specify altitude of
product if over 2000 feet (610m)
Sides
Back
Base
Natural Gas
Propane
6(152)
6(152)
Non-combustible
4” WC (10 mbar)
10” WC (24 mbar)
NOTE:
Installation clearance reductions are
applicable only where local codes permit
Note: For use with Natural & L.P Gas only
Item #:______________________________
Models: All G24 Series
Product Name: Heavy-Duty Gas Griddles
Continuous product improvement is a Garland policy. Specifications and design are subject to change without notice.
Printed in USA
Form #G24G/GTHX (02/16/07)
G2
4 S
er
ie
s H
ea
vy
-D
ut
y G
ri
dd
le
s
M
od
el
s: G
24 -
24
, 3
6, 4
8, 6
0, 7
2
Model
W
G24-24G
G24-24GTHX
24” (610mm)
G24-36G
G24-36GTHX
36” (914mm)
G24-48G
G24-48GTHX
48” (1219mm)
G24-60G
G24-60GTHX
60” (1524mm)
G24-72G
G24-72GTHX
72” (1829mm)
(327mm)
1" NPT GAS INLET
(G24-48,G24-60,G24-72)
12-7/8"
(38mm)
3/4" NPT INLET
(G24-24,G24-36)
1" NPT GAS INLET (G24-48,G24-60,G24-72)
3/4" NPT INLET (G24-24,G24-36)
*HEIGHT OF GRIDDLE PLATE
W
(38 mm)
13-7/8"
6-3/4"
(772mm)
1-1/2"
30-3/8"
(171mm)
(259mm)
(352 mm)
1-1/2"
10-1/4" *
4" (102mm)