Garland Enodis 36ER32 Specifications Download Page 2

Garland Commercial  

Industries, LLC

185 East South Street

Freeland, PA 18224

Phone: (570) 636-1000

Fax: (570) 636-3903

Garland Commercial Ranges Ltd

1177 Kamato Road,  

Mississauga, Ontario  

L4W 1X4 CANADA

Phone: 905-624-0260

Fax: 905-624-5669

Enodis UK LTD

Swallowfield Way,  

Hayes, Middlesex  

UB3 1DQ ENGLAND

Telephone: 081-561-0433

Fax: 081-848-0041

36

 E S

eri

es

 H

ea

vy

 D

ut

y A

ll P

urp

os

e T

op

 R

an

ge

Form# 36ER32 (07/07)

MODEL

TOTAL 

kW

3-PHASE

kW PER PHASE

ALL VOLTAGES

NOMINAL AMPERES PER LINE

SINGLE PHASE

THREE PHASE

208V

240V

460V

X-Y

Y-Z

X-Z 208V 240V 460V X

Y

Z

X

Y

Z

X

Y

Z

36ER32

21.5

6.5

5

10

103

91

47

69 48 64 61 43 56 31 22 28

36ES/ET32

15

5

5

5

72

64

33

42 42 42 37 37 37 19 19 19

36ERC32

20.4

5.4

5

10

98.1

85

NA

65 44 63 56 38 54 NA NA NA

CLEARANCES

ENTRY

TO COMBUSTIBLE 

WALL

CRATED

UNCRATED

SIDES

REAR

41-1/4" 

(1048mm)

36-1/4" 

(921mm)

3" (76mm)

1-1/2" 

(38mm)

 36" 

[914mm]

 24" 

[610mm]

 6" 

[152mm]

 33-3/4" 

[857mm]

 14-1/2" 

[368mm]

 36" 

[914mm]

 30" 

[762mm]

 18" 

[457mm]

 15" 

[381mm]

18"

[457mm]

 63" 

[1600mm]

With "DD"

Hi Shelf

6"

[152mm]

31-3/8"

[797mm]

With STD.

Backguard

REAR

ELECTRICAL

6"

[152mm]

6"

[152mm]

NOTE: Add 2" [51mm]

to depth for RC Models

Modular Top

12" [305mm]

NOTE:  For ranges with convection oven(s), (models with 

suffix ‘RC’), air circulation is required for proper operation 

of fan motors. These models must not be dais mounted or 

installed with out legs. 
Garland products are not approved or authorized for home 

or residential use, but are intended for commercial ap-

plications only. Garland will not provide service, warranty, 

maintenance or support of any kind other than in commer-

cial applications.

Shipping Cubic Feet 51, all models except 36ET32 

which is 20 Cu Ft.