4. TEST PROCEDURES AND TROUBLESHOOTING

CAUTION

-DISCONNECT THE POWER SUPPLY CORD FROM THE WALL
OUTLET WHENEVER REMOVING THE CABINET FROM THE UNIT.
PROCEED WITH TESTS ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITORS AND REMOVING THE LEAD WIRES ON
THE PRIMARY WINDING OF  THE HIGH VOLTAGE TRANSFORM-
ERS FOR LOWER AND UPPER MAGNETRONS.

(SEE FIGURE 3)

COMPONENT

HIGH-VOLTAGE
TRANSFORMER

1) Measure the resistance:
    With an ohm-meter on R x1 scale.
  a. Primary winding;
  b. Filament winding;
  c. Secondary winding;
2) Measure the resistance:
    with an ohm-meter on highest scale.
  a. Primary winding to ground;
  b. Filament winding to ground;

CHECKOUT  PROCEDURE

RESULT

Normal reading:

   Approximately 1.0 ohms
   Less than 1 ohm.
   Approximately 83 ohms
Normal reading:

Infinite ohms.
Infinite ohms.

Note: Remove varnish of measured point.

PRIMARY
WINDINGS

  Secondary
  Windings

Filament
Windings

    Figure 2

Figure 3

A. TEST PROCEDURES

F. CHANGING POWER SUPPLY CORD
   (See exploded view on page 5)
   (1) Unfasten 1 screw for ground and pull out the
        2 wires of the power cord from the terminal plate.
   (2) Remove 1 screw for the bottom bracket  of the
        cord bushing.
   (3) Install the new power supply cord with the
        reverse procedure of above (1) to (2).

  WARNING:
   For changing the power supply cord, never use
   other than the following.

 Key No. Order No.                     Parts Name

5       617 140 1561

Power cord Ass’y

6       617 140 1332

Cord bush

7       617 140 1349

Bottom bracket

 

5. DISASSEMBY INSTRUCTIONS

Summary of Contents for EM-C120

Page 1: ...erating compartments check the magnetron wave guide or transmission line and cavity for proper alignment integrity and connections d Any defective or misadjusted components in the interlock monitor do...

Page 2: ...the area emitting the highest reading switch the meter to SLOW RESPONSE and take a reading for minimum of three 3 seconds We recommended the pattern outline shown below when the door surface is survey...

Page 3: ...ea sured with the following power output 1 1 Fill two beakers one liter of tap water respec tively 2 Use an accurate thermometer and measure each water temperature respectively 2 Place beakers side by...

Page 4: ......

Page 5: ...ng to ground CHECKOUT PROCEDURE RESULT Normal reading Approximately 1 0 ohms Less than 1 ohm Approximately 83 ohms Normal reading Infinite ohms Infinite ohms Note Remove varnish of measured point PRIM...

Page 6: ...g consumable components will be replaced Maintenance light in window display indicates when accumulative cooking time reaches 1 250 hours Light 1 Magnetron Tube Part No 415 002 7702 2 Printed Circuit...

Page 7: ...t have special characteristics for safety and must be replaced using parts listed in this manual All service on M W ovens should be performed by a qualified technician using approved testing equipment...

Page 8: ...istics for safety and must be replaced using parts listed in this manual All service on M W ovens should be performed by a qualified technician using approved testing equipment Customers should not at...

Page 9: ......

Page 10: ...characteristics for safety and must be replaced using parts listed in this manual All service on M W ovens should be performed by a qualified technician using approved testing equipment Customers shou...

Page 11: ...istics for safety and must be replaced using parts listed in this manual All service on M W ovens should be performed by a qualified technician using approved testing equipment Customers should not at...

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ...h Blue NC Inside Light Blue Interlock switch Orange White Pink NO Insde Red wire Transformer Transformer Red wire Red wire Red wire Filament Winding Filament Winding Lower Magnetron Magnetron Upper Up...

Page 19: ......

Page 20: ......

Reviews: