GENERAL INFORMATION

Uncrating

Carefully remove the units from the carton. 

Remove all packing material from the units. On stainless steel 

and brushed chrome units, the protective material covering 

the stainless steel and brushed chrome should be removed.

Statutory Regulations 

The installation and connection should comply with current 

codes in Canada – The Canadian electrical code part 1 and / 

or local codes. In USA – The National Electrical Code ANSI / 

NFPA – Current Edition, and include

1.  Switch panel size

2.  Overload protection

3.  Wire type

4.  Wire size

5.  Temperature limitations of the wires

6.  Method of connection (Cable, Conduit, etc.)

Rating Plate

Ensure that the electrical supply conforms with the electrical 

characteristics shown on the rating plate.

For serial plate location (showing voltage and loading), wall 

clearances and required temperate ratings for supply cable, 

refer to the section for the model being installed.

INSTALLATION

E22 Series Installation Of Banking Plates

All units may be installed independently or banked with 

other E22 or G22 Series equipment. To ensure a matching 

and permanent fit between units, two banking plates are 

available for each unit to be installed. One at the front and 

one at the rear of each two units being banked together.  

(If 2-1/2” (64mm) legs are supplied with the unit, discard 

leveling bolts and replace with the 2-1/2” (64mm) legs.

1.  Level each unit by adjustment of leveling bolts or legs. 

Use a spirit level and level unit four ways; across front and 

back and down left and right edges. Level all other units 

to the first unit.

 

Note: Griddles may not rest evenly on the unit body if 

units are not leveled.

2.  Remove sheet metal screws at rear of unit.

3.  Attach one banking plate in position at rear by placing 

the 1/4” (6 mm) diameter holes in the banking plate 

over the screw holes in the rear of units and fasten by 

replacing the sheet metal screws removed in Step 2.

4.  Push units into position on counter top or back bar.

5.  Remove lower front panels, by removing the acorn nuts 

on each side of the panel. NOTE: CARE SHOULD BE TAKEN 

WHEN REMOVING LOWER FRONT PANEL, SO THAT THE 

WIRES ARE NOT DISENGAGED FROM THE SWITCHES OR 

CONTROLS. 

6.  Place the second banking plate in position so that the 

5/8” (16mm) diameter Holes in the banking plate fit 

over the lower front panel mounting bolts, with the 1/4” 

(6mm) diameter holes in the banking plate at the bottom.

7.  Secure the banking plate to both units, with the sheet 

metal screws provided with the banking plates.

8.  Replace and secure the lower front panels

E24 Series Installation of Banking Plates

All units may be installed independently or banked with 

other E24 or G24 Series equipment. To ensure a matching 

and permanent fit between units, a front banking plate is 

supplied with each unit. If 2 1/2”(64 mm) legs are supplied 

with nit, discard leveling bolts and replace with 2 1/2”  

(64 mm) legs.

Summary of Contents for E24-12H

Page 1: ... 1177 Kamato Road Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis UK LTD Swallowfield Way Hayes Middlesex UB3 1DQ ENGLAND Telephone 081 561 0433 Fax 081 848 0041 Part P66 01 25 08 2006 Garland Commercial Industries Inc FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTA...

Page 2: ...e of california to cause cancer and or birth defects or other reproductive harm Installation and servicing of this product could expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer ...

Page 3: ...tand Installation 5 Fryers Model E22 14F E22 28FT 5 Hot Plate Model E22 12H 6 Griddles Model E22 18G E22 24G E22 36G 6 Sandwich Griddle Model E22 18SG 7 Food Warmers Model E22 15W E22 15WP E24 32W E24 32WP 7 Pizza Ovens Model E22 22P E22 22PP 8 Broilers Models E22 12B E22 24B E22 36B 8 Hot Plate Model E24 12H 9 Fryers Model E24 31F E24 31SF E24 31FBL E24 31SFBL E18F E18SF E18FBL E18SFBL 9 Griddles...

Page 4: ...ling bolts and replace with the 2 1 2 64mm legs 1 Level each unit by adjustment of leveling bolts or legs Use a spirit level and level unit four ways across front and back and down left and right edges Level all other units to the first unit Note Griddles may not rest evenly on the unit body if units are not leveled 2 Remove sheet metal screws at rear of unit 3 Attach one banking plate in position...

Page 5: ...tal screws in the main bottom of units to be placed on the outer sides of the stand 4 Place units in desired position on the counter stand securing the first unit with sheet metal screws removed in paragraph 3 Insert sheet metal screws through the 9 32 7 mm diameter holes in the stand into hole from which the sheet metal screws were removed 5 Connect banking plates as described in E24 Series Insta...

Page 6: ...ottom to access raise the rear element and remove the bowl Wall Clearances Do not install closer to a wall of combustible material than Sides 1 1 2 38mm Back 1 1 2 38mm Electrical Connection For supply connection use wire suitable for 75 C 167 F Electrical connection may be made though the knockout at the rear of the unit to the terminal box located on the inside rear of the unit Access to the ter...

Page 7: ...wer Wall Clearances Do not install closer to a wall of combustible material than Sides 1 25mm Back 1 1 2 38mm Electrical Connections For supply connection use wire suitable for 90 C 194 F Refer to griddle section for electrical connection griddle thermostats and calibration instructions Controls The switch on the left of the unit is an infinite switch used in conjunction with an amber pilot light ...

Page 8: ...s seldom necessary and should not be resorted to unless experience with cooking results definitely proves that the control is not maintaining the temperature to which the dial is set To check oven temperature when calibrating use only a reliable mercury thermometer or preferably an oven pyrometer To check calibration proceed as follows 1 Place the thermocouple of the test instrument or reliable me...

Page 9: ... the rear of the unit to the terminal block located on the inside left rear of the unit Access to the terminal box is gained by removing the back cover plate at the rear of the unit Controls Infinite switches are used to control the heating units Hi to 5 High heat 5 to 3 Medium heat 3 to Lo Low heat Setting of the switches between the numbers will give intermediate heat Switches are reversible and...

Page 10: ...urn 30 F 17 C 7 Replace the thermostat dial and repeat steps 2 through 4 to verify that the correct adjustment has been made Griddles Model E24 24G E24 36G E24 48G E24 60G E24 72G Serial Plate Location The serial plate is located on the grease drawer slide to access remove the grease drawer Wall Clearances Do not install closer to a wall of combustible material than Sides 1 25mm Back 1 1 2 38mm El...

Page 11: ...oser to a wall of combustible material than Sides 5 127mm Back 5 127mm Electrical Connections For supply connection use wire suitable for 90 C 194 F Electrical connection may be made through the knockout at the rear of bottom of the unit to the terminal block located behind the lower front panel Access to the terminal block is gained by removing the 10 24 machine screws and hinging the lower front...

Page 12: ......