Part # 1009080 Rev 4 (01/25/08)
Page 6
INTRODUCTION
Your new equipment should be given regular care and
maintenance . Periodic inspections by your dealer or a
qualified service agency are recommended .
This product has been certified as commercial cooking
equipment and must be installed by professional personnel
as specified .
Rating Plate
When corresponding with the factory or your local
authorized factory service center regarding service problems
or replacement parts, be sure to refer to the particular unit
by the correct model number (including the prefix and suffix
letters and numbers) and the warranty serial number . The
rating plate affixed to the unit contains this information . The
rating plate is located on the main back panel behind the
unit, on hot plates . For griddles the plate is located on the
grease drawer slide, remove the grease drawer to access .
Before attempting the electrical connection, the rating
pate should be checked to ensure that the unit’s electrical
characteristics and the supply characteristics agree .
LOADING CHART E24-H Hot Plate
Model
Total Kw
Load
Nominal Amperes Per Line
3 Phase
Single Phase
240V
208V
240V
208V
X
Y
Z
X
Y
Z
E24-12H
4 .2
15 .2
8 .8
8 .8
17 .5
10 .1
10 .1
17 .5
20 .2
Export voltage available on request – Specify wiring required
kW loadings are reduced on 220 volt systems .
Standard wiring 240 volt (220/240) or 208 volt (197/219) single or three phase