GENERAL INFORMATION
SAFETY
1. Check the crate for possible damage sustained during
transit. Carefully remove the unit from the crate and
again check for damage. Any damage to the appliance
must be reported to the carrier immediately.
2. The type of voltage supply that the equipment was
manufactured for at the factory is noted on the data plate
on the equipment. This type of supply must be used.
3. Do not remove permanently affixed labels, warning or
data plates form the appliance, this may void approvals
and create a safety hazard.
The Garland E22 series complies with the standards CSA
C22.2 no. 109 – latest edition and UL197 – latest edition. The
installation and connection of this appliance must comply with
current codes. In Canada – the Canadian Electrical Code Part
1 and in the USA – the National Electrical Code.
• A qualified person must make the installation in
accordance with the authority having jurisdiction and
local codes.
• This unit must only be operated by a qualified person.
DO NOT operate without reading this manual.
• DO NOT operate this appliance unless all service and
access panels are in place and fastened properly.
• DO NOT attempt to repair or replace any part of this
appliance unless all main power supplies have been
disconnected.
• DO NOT clean this appliance unless the power supply is
disconnected.
WARNING: To avoid serious personal injury:
• USE EXTREME CAUTION in setting up, operating
and cleaning these appliances to avoid coming in contact
with hot surfaces. Wear suitable protective clothing or
use proper utensils to prevent the risk of burns.
NOTE:
All warning labels and markings on this
appliance, which call attention to further dangers and
necessary precautions.
SPECIFICATIONS
Models: E22-36-36GM(X) E22-36-45GM(X)
E22-36-48GM(X)
E22-36-56GM(X)
E22-36-60GM(X) E22-36-68GM(X)
E22-36-72GM(X)
X suffix use electronic thermostats
Total kW
Loading
kW Loading Per Phase
Nominal Amps Per Phase
Single Phase
Three Phase
240V 208V
240V
208V
240V
208V
240V
208V
X-Y
Y-Z
X-Z
X-Y
Y-Z
X-Z
X
Y
Z
X
Y
Z
6.7
6.7
3.35
---
3.35
3.35
---
3.35
27.92
32.21
24.22
13.96
13.96
27.95
16.11
16.11
The E22-36-36GM(X) is for installation in non-combustible locations only. All others should be installed with the
following minimum clearances from combustible material.
Minimum Installation Clearances
Left & Right Sides
Rear
Type of Floor Base
1/2” (12.5mm)
1/2” (12.5mm)
Combustible