SELECTION OF FIBER OPTIC CABLE (FOC)
Fiber optical cable is available in several formats; simplex, duplex, and breakout. FOC is
also available in various diameters and tensile strengths. Tensile strength is important for
longer life expectancy.
Simplex FOC
is desirable for loop operations. It has one optical conductor and can be
connected from the transmitter of one Link/Repeater to the receiver of the next
Link/Repeater in the loop.
Duplex FOC
has two optical conductors and is a convenient form when connecting two
units Point-to-Point.
Breakout cable
is a duplex FOC that has extra strength members added and is suit-
able for burial.
The following are the specifications of multi-mode FOC offered by DYMEC and is the recommended
minimum standard for optimum performance.
METRIC-TO-ENGLISH UNIT CONVERSIONS
MULTIPLY
BY
MULTIPLY
BY
Millimeters
→
→
→
→
Inches
0.03937
Kilograms
→
→
→
→
Pounds
2.2046
Centimeters
→
→
→
→
Inches
0.3937
Kg/Km
→
→
→
→
Pounds/1,000 Ft
0.67197
Meters
→
→
→
→
Feet
3.2808
Newtons
→
→
→
→
Pounds
0.22481
Kilometers
→
→
→
→
Feet
3280.8
N/Cm
→
→
→
→
Pounds/inch
0.57101
Kilometers
→
→
→
→
Miles
0.62137
Simplex Duplex Breakout
Fiber Count
1
2
2
Fiber Material
Glass
Glass
Glass
Attenuation
[dB/km]
3
3
3
Diameter
[mm]
3.0
3.0 x 6.5
7.0
Weight
[kg/km]
8.0
16.0
50
Tensile load - Short Term
[N]
500
1000
1200
Tensile load - Long Term
[N]
300
500
500
Minimum Bend Radius - With Load
[cm]
5
5
14
Minimum Bend Radius - No Load
[cm]
3
3
7
Crush Resistance
[N/cm]
750
750
2200
Impact Resistance
[Cycles]
1000
1000
2500
Flex Resistance
[Cycles]
7500
7500
2000
Operating Temperature
[
o
C] -40
o
to +85
o
-40
o
to +85
o
-40
o
to +85
o
Storage Temperature
[
o
C] -55
o
to +85
o
-55
o
to +85
o
-55
o
to +85
o
Summary of Contents for 5843HRT