7.5  Wiring Diagram:  

Model DHP1000 (230-400-460V/3/50-60 Hz)

(Page 1 of 2)

H4

H3

H2

H1

FU2

FU3

B100-3683-5

MICR

ON

L1

L3

H5

208V

230V

H5

400V

H5

460V

H5

FA

CT

OR

Y SE

TO 460V

FU1

24/120 V

AC 

SEC

OND

AR

Y

100V

A

208/230/400/460 V

AC 

PRIM

AR

Y

H5

CO

M

H3

230V

H4

208V

H2

400V

X3

X2

X1

H1

120V

24V

460V

COMPRESSOR

TO LINE 22

21

20

18

19

17

16

15

14

13

L1

L3

L2

PE

HEA

TER HARNESS

1L2

L3

TB2

TB2

PE

T3

T2

H1

HEA

TER 1

FAN 2 HARNESS

FPS 2

FAN 2

REF SHEE

T 02 LINE 12

REF SHEE

T 01 LINE 20

03

10

11

12

09

08

07

06

05

04

L3

L3

L3

L2

L2

02

01

00

PE

L1

L1

L1

L3

L2

TB1

L1

L3

L2

CONT 1

DISC

ONNEC

T

PE

TB2

T1

T2

T3

T3

T2

T3

TB2

PE

T2

T3

T2

FAN 1 HARNESS

FPS 1

FAN 1

T1

T1

T1

COMPRESSOR HARNESS

43

42

X

TO SHEE

T 02

40

41

39

38

37

36

35

N

TO SHEE

T 02

25

(4 T

er

minal 

Blocks)

TB2

32

33

34

X

31

30

X

29

28

27

26

FR

OM LINE 21

24

23

22

L3

L1

(4 T

er

minal 

Blocks)

TB2

N

N

L3

L1

L1

L3

ELEC

TRIC

AL SUPPL

Y

480V

AC/3PH/60HZ/GND

CONT 1

-1NC

-2NC

H2

M

TR3

L3

L2

T3

T2

L1

T1

M

TR2

M

TR1

Summary of Contents for SPX FLOW DHP Series

Page 1: ...ed Type Compressed Air Dryer Models DHP130 DHP200 DHP300 DHP500 DHP750 DHP1000 FOR M NO 5003971 R EVI S ION 07 2016 R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH...

Page 2: ...UIDE 7 5 0 REFERENCE 8 5 1 Sizing 8 5 2 Engineering Data 9 6 0 DIMENSIONS WEIGHTS 10 7 0 DRAWINGS 11 7 1 Process Gas Refrigeration Flow Diagram Models DHP130 and DHP200 11 7 2 Process Gas Refrigeratio...

Page 3: ...lant It was received in good condition by the carrier and was so acknowledged Check for Visible Loss or Damage If this shipment shows evidence of loss or damage at time of delivery to you in sist that...

Page 4: ...he dryer inlet outlet connections from the piping External piping must be properly supported The installation of a flexible connection or vibration dampener within the air gas stream prior to the drye...

Page 5: ...nection NOTE Strainer and water regulating valve are supplied on water cooled models 1 4 Electrical Connections IMPORTANT Use copper supply wires only A Dryer is designed to operate on the volt age ph...

Page 6: ...temperature 120 F 49 C D Maximum ambient temperature Air cooled models 110 F 43 C Water cooled models 130 F 54 C E Minimum ambient temperature 40 F 4 C Condensate Draining Drain Push to Test On Off Sw...

Page 7: ...e NOTE Failure to perform step 3 within 25 seconds of com pleting step 2 will cause the unit to revert back to the previous setting NOTE In the event of a brief or extended period of power loss the un...

Page 8: ...e separator filter elements become loaded with solid particles 2 Procedure for Separator Filter Element Replacement THIS FILTER IS A PRESSURE CONTAINING DEVICE DEPRESSURIZE BEFORE SERVICING a Isolate...

Page 9: ...ss dryer 1 Excessive air flow 2 Freezing of moisture in evaporator because of refrigeration system fault 3 Separator filter element clogged Check flow rate See D below Replace filter element C Dew poi...

Page 10: ...emperature and 100 F ambient temperature and 60 Hertz operation MODEL RATED FLOW scfm m3 hr DHP130 DHP200 DHP300 DHP500 DHP750 DHP1000 130 200 300 500 750 1000 221 340 510 850 1275 1700 Table 2 Capaci...

Page 11: ...N A 1 2 2 0 2 8 3 3 Electrical Data Nominal Voltage 115 1 60 208 230 3 60 Min Max Voltage 104 127 187 253 Input Power Rated Flow watts 932 1280 1255 1962 2910 4120 Rated Load Amps 10 2 13 0 7 5 10 4...

Page 12: ...651 32 15 817 32 15 817 32 15 817 32 15 817 C 2 50 63 5 2 50 63 5 2 50 63 5 2 50 63 5 2 50 63 5 2 50 63 5 D 23 62 600 23 62 600 30 15 766 30 15 766 30 15 766 30 15 766 E 17 62 448 17 62 448 30 15 766...

Page 13: ...IEF VALVE PRE COOLER REHEATER CONDENSATE DRAIN AUTOMATIC ELECTRIC DRAIN SERVICE VALVE MANUAL DRAIN AIR AIR HEAT EXCHANGER HIGH TEMPERATURE SWITCH OPTIONAL EVAPORATOR CARTRIDGE TYPE MOISTURE SEPARATOR...

Page 14: ...ESS FITTING FITTING ACCESS PRESSURE VALVE RELIEF HEAT EXCHANGER REHEATER PRE COOLER AIR AIR SWITCH STANDARD CONDENSER DETAIL OPTIONAL WATER COOLED TYPE CARTRIDGE SEPARATOR MOISTURE OPTIONAL GAUGE OPTI...

Page 15: ...2 L1 N L1 CONT 1 T1 T2 TO GROUND STUD PE T1 T2 TO GROUND STUD PE FAN 1 HARNESS C 1 FAN 1 MTR2 FPS 1 COMPRESSOR MTR1 DRAIN NEUTRAL COMPRESSOR ON L1 L1 N L1 1 1 N L1 1L1 N 1 N GROUND STUD 6 7 J5 3 5 4 1...

Page 16: ...1 L3 L2 PE HEATER HARNESS 1L2 L3 TB2 TB2 PE T3 T2 H1 HEATER 1 FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 18 REF SHEET 01 LINE 19 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2 02 01 00 PE TB1 L1 L2 L3...

Page 17: ...10 09 08 06 05 04 03 X X 02 01 00 FROM SHEET 01 X X X X THERMISTER CONTROL BOARD DRAIN NEUTRAL DRAIN LINE THERMISTER NEUTRAL 3 N N HPS 1 LINE 1 1 1 TB2 GRN YELLOW DRAIN HARNESS DRAIN HARNESS PE TB2 3...

Page 18: ...L3 TB2 TB2 PE T3 T2 H1 HEATER 1 FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 12 REF SHEET 01 LINE 20 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2 02 01 00 PE L1 L1 L1 L3 L2 TB1 L1 L3 L2 CONT 1 DISCONN...

Page 19: ...08 06 05 04 03 X X 02 01 00 FROM SHEET 01 X X X X THERMISTER CONTROL BOARD DRAIN NEUTRAL DRAIN LINE THERMISTER NEUTRAL 3 N N HPS 1 LINE 1 TB2 GRN YELLOW DRAIN HARNESS DRAIN HARNESS PE TB2 3 TB2 PE X 3...

Page 20: ...18 7 6 Wiring Diagram Models DHP300 through DHP1000 575 460 3 60 Transformer Pack...

Page 21: ...3232829 3232830 5002924 3232832 3232829 3232830 5002924 3232832 Low Refrigerant Pressure Switch 4006372 4006372 4006372 4006372 4006372 4006372 4006372 4006372 High Refrigerant Pressure Switch 3230764...

Page 22: ...20 NOTES...

Page 23: ...part THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR STATUTORY AND IS EXPRESSLY IN LIEU OF THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARR...

Page 24: ...low com www spxflow com deltech Improvements and research are continuous at SPX FLOW Inc Specifications may change without notice ISSUED 07 2016 Form No 5003971 Revision F COPYRIGHT 2016 SPX FLOW Inc...

Reviews: