EQUIPMENT CHECK
Before uncrating, check the packing slip carefully to
be sure all the parts have been received. All
accessories are listed as separate items on the
packing slip, and small important accessories such
as relief valves can be overlooked or lost. After
every item on the packing slip has been checked off,
uncrate carefully. Register a claim with the carrier
for lost or damaged equipment
.
Customers are cautioned to provide
adequate protection, warning and safety
equipment necessary to protect personnel
against hazards involved in installation and
operation of this equipment in the system or
facility.
STORAGE
Your Gardner Denver Blower was packaged at the
factory with adequate protection to permit normal
storage for up to six (6) months.
If the unit is to be stored under adverse conditions or
for extended periods of time, the following additional
measures should be taken to prevent damage.
1. Store the blower in a clean, dry, heated (if
possible) area.
2. Make certain inlet and discharge air ports are
tightly covered to prevent foreign material from
entering the air box.
3. All exposed, non-painted surfaces should be
protected against rust and corrosion.
4. Provide adequate protection to avoid
accidental mechanical damage.
5. In high humidity or corrosive environments,
additional measures may be required to prevent
rusting of the blower internal surfaces.
6. To prevent rusting of gears, bearings, etc., the oil
reservoirs may be filled with normal operating oil.
Before running the blower, drain the oil and
replace to the proper operating level with clean,
fresh lubricant.
7. Rotate the blower shaft (10 to 25 turns) weekly
during storage. Inspect the blower shaft (near the
shaft seal area) monthly and spray with rust inhibitor
if needed.
8. For long term storage (over six (6) months),
contact Gardner Denver Compressor Division
Customer Service for recommendations.
REMOVING PROTECTIVE MATERIALS
The shaft extension is protected with rust inhibitor
which can be removed with any standard solvent.
Follow the safety directions of the solvent
manufacturer.
Blower inlet and outlet are temporarily capped to
keep out dirt and other contaminants during
shipment. These covers must be removed before
start-up.
The internal surfaces of all Sutorbilt units are mist
sprayed with a rust preventative to protect the
machine during shipment. Remove this film upon
initial startup, using any commercial safety solvent.
Position the blower so that the inlet and discharge
connections are in the vertical position (vertical
airflow). On vertically mounted units, it will be
necessary to lay the unit on its side supporting the
ends of the unit so as not to restrict the port on the
bottom side. Place a shallow pan on the under side
of the unit. With the blower disconnected from
power, spray the solvent in the top port, rotating the
impellers by spinning the shaft manually. Continue
this procedure until the unit is visibly clean.
Rotating components will cause severe
injury in case of personal contact. Keep
hands and loose clothing away from blower
inlet and discharge ports..
Summary of Contents for LEGEND P Series
Page 19: ...SB 7 622 Page 18 SECTION 5 MAINTENANCE FIGURE 5 1 PULLER PLATE SK2154...
Page 20: ...SB 7 622 Page 19 FIGURE 5 2 GEAR DRIVEN SK2150...
Page 21: ...SB 7 622 Page 20 FIGURE 5 3 MECHANICAL SEAL INSTALLATION TOOL SK2152...
Page 22: ...SB 7 622 Page 21 FIGURE 5 1 BEARING PRESS TOOL MECHANCIAL SEAL UNITS SK2156 FIGURE 5 4...
Page 33: ...SB 7 622 Page 32 SECTION 8 PARTS LIST 300GAF810 B Ref Drawing...
Page 35: ...SB 7 622 Page 34 300GAG810 A Ref Drawing...
Page 37: ...SB 7 622 Page 36 300GAH810 A Ref Drawing...
Page 39: ...SB 7 622 Page 38...