Never paint, lubricate or alter a relief valve. Do not plug vent or restrict
discharge.
Operation of the unit with improper relief valve setting can result in severe
personal injury or machine damage. Ensure properly set valves are installed
and maintained.
Oil Level Gauge -
This gauge is located on the oil reservoir and indicates the oil level. See “Oil Level
Gauge”, Figure 5-4, page 57, for how to read oil level.
Minimum Discharge Pressure/Check Valve -
An internal spring-loaded minimum pressure valve is used
in the final discharge line to provide a positive pressure on the coolant system of the compressor even if
the air service valve is fully open to atmospheric pressure. This valve also functions as a check valve to
prevent back flow of air from the shop air line when the unit stops, unloads, or is shut down.
The valve incorporates an orifice which, when air is flowing through it, maintains pressure in the oil
reservoir. A spring-loaded piston valve senses air pressure on the upstream (reservoir) side of the valve.
When the system pressure rises, the spring is overridden and the valve opens to full porting.
Inlet Valve
(Figure 4-1, page 24)
-
The Inlet valve restricts the inlet to control delivery and closes to
unload the compressor. At shutdown, the inlet valve closes to prevent the back flow of air.
The inlet valve position is controlled by air pressure in its piston cylinder, which is controlled by the
"AirSmart" through the magnetic unloader solenoid valve. When the top of the cylinder is pressurized, the
inlet opens for full air delivery. When pressure is relieved from the cylinder, the inlet valve closes to
restrict air flow and compressor delivery.
Magnetic Unloader Solenoid Valve
(Figure 4-1, page 24)
-
This valve controls the position of the inlet
valve in response to signals from the "AirSmart". When de-energized, pressure is relieved from the top of
the inlet valve cylinder to unload the compressor. When the solenoid valve is energized, reservoir
pressure is supplied to the top of the cylinder to load the compressor.
Check Valve
(Figure 4-1, page 24)
-
This valve is normally closed while the compressor is loaded or
stopped. While running unloaded, it opens to admit a small amount of purge air to the compressor inlet.
This reduces compressor knock, and provides enough air to pressurize the controls during startup.
Blowdown Valve
(Figure 4-1, page 24)
-
The blowdown valve is a two-way solenoid valve which is piped
into the oil reservoir outlet ahead of the minimum pressure valve. When the solenoid is de-energized, the
valve opens and the coolant system is blown down. When the solenoid is energized, the valve closes to
allow the coolant system to pressurize.
System Pressure Transducer
(Figure 4-1, page 24)
-
This transducer is connected after the minimum
pressure valve. It converts the pressure in the plant air system into an electrical signal for use by the
"AirSmart" controller for modulation and control.
Summary of Contents for INTEGRA AIRSMART EFC99J
Page 11: ...13 20 600 Page 10 Figure 1 2 COMPRESSOR ILLUSTRATION 302EFC797 B Ref Drawing...
Page 31: ...13 20 600 Page 30 307EBE546 D Ref Drawing Page 2 of 2...
Page 33: ...13 20 600 Page 32 315EBE546 A Ref Drawing Page 2 of 2...
Page 35: ...13 20 600 Page 34 308EBE546 D Ref Drawing Page 2 of 2...
Page 37: ...13 20 600 Page 36 313EBE546 C Ref Drawing Page 2 of 2...
Page 39: ...13 20 600 Page 38 314EBE546 A Ref Drawing Page 2 of 2...
Page 41: ...13 20 600 Page 40 317EBE546 A Ref Drawing Page 2 of 2...
Page 43: ...13 20 600 Page 42 309EBE546 D Ref Drawing Page 2 of 2...
Page 45: ...13 20 600 Page 44 316EBE546 A Ref Drawing Page 2 of 2...
Page 47: ...13 20 600 Page 46 310EBE546 C Ref Drawing Page 2 of 2...
Page 49: ...13 20 600 Page 48 311EBE546 C Ref Drawing Page 2 of 2...
Page 51: ...13 20 600 Page 50 312EBE546 C Ref Drawing Page 2 of 2...
Page 74: ......