10 Service and maintenance
43
b) Control-cabinet inlet filter (-4- Fig. 21)
Fig. 22
Fig. 23
Perform filter mat change as follows:
•
Open the louver grilles of the inlet filter (Fig. 22).
•
Remove the filter pad.
•
Insert the new filter pad into the louver grille. Ensure
that the smooth side (-A- Fig. 23) of the filter pad
faces the air inlet side.
•
Place the louver grille back onto the filter housing.
Changing times for the filter mat
The operating modes and the quality of the suctioned
air (e.g., dust content) has a strong influence on the
filter service life.
The filter should be checked on a weekly basis,
eventually daily basis, for dust build-up.
In these cases the intervals between changes may be
shorter.
10.13
Inspection of the compressor stage
DANGER
Only perform checks and carry out work on
the screw compressor when the unit is out
of operation, depressurized, and secured
from being switched on again!
CAUTION
Caution when draining hot water: risk of
scalding!
•
Allow the unit to cool down first.
NOTICE
When removing the cover, water (3.17 USgal)
may escape from the compressor. Please place
an appropriate reservoir underneath it to collect
the water.
Fig. 24
Perform an inspection of the compressor stage as
follows:
•
Shut down the machine.
•
Switch off the main switch or disconnect the
machine from the power supply.
•
Remove the retaining bolts from the side cover of
the compressor and take off the cover (-1- Fig. 24).
•
Assess the condition of the compressor. The
inspection plan describes everything you need to
consider.
Summary of Contents for EnviroAire 15
Page 1: ...Original Operating and Service Manual 15 22 kW USA Id no ZS1093133 00 June 2012...
Page 2: ......
Page 52: ...12 Annex 50 Fig 29 all dimensions in Inches...
Page 53: ......
Page 54: ......
Page 55: ......