Maintenance and repair
7.2 Maintenance table
Interval
(Operating hours [Bh])
Maintenance activities
Chapter
Monthly
Check the terminal box and cable inlet holes for leaks and if
necessary re-seal.
—
Clean the ventilation slots on the machine and the motor
cooling ribs.
With the exhaust line connected, it must be checked regularly
for pollution.
—
Check the oil level
7.2.1
Depending on how dirty the
sucked medium is
Clean the non-return valve
—
Clean the micro filter
Depending on the applica-
tion, at least monthly
Drain the condensate of the silencer
3,000 Bh,
after 6 months at the latest
Check the pipes and screws for leaks and ensure their tight
fit and if necessary re-seal or re-tighten.
—
8,000 Bh
Oil change
The oil change interval strongly depends on how the machine
is loaded (operating time, operating conditions, etc.) and the
type of oil used. Extreme load can reduce the lifetime of oil.
The specified interval of 8,000 h only applies to oil that has
been delivered or is approved by Elmo Rietschle.
7.2.1
At least 1 x per year
Check the cooling air fan for tight fit and damage
As per manufacturer's
instructions
Motor (maintenance, lubrication and cleaning)
Yearly
Integrated frequency converter (maintenance-free)
Refer
to the
ELCB-in-
structions
Functional test of safety devices and safety-related measur-
ing, control and regulation devices
40,000 operating hours
General overhaul of the central vacuum unit (Elmo Rietschle
Service)
—
7.3 Preparing maintenance works
a) Switch the plant off electrically and secure it against unexpected restart.
b) Bleed the machine to atmospheric pressure.
c) Allow the machine to fully cool down.
Exception: Oil change, here the pump shall be still hot, because oil can then better flow off.
d) Post the warning sign "Caution, maintenance works!".