Installation
5.5.1 Electrical connection of the control
The control requires its own 1~ connection. It is connected to the terminal -10X1 in the control box (Fig. 8).
The control unit is internally protected by a fuse (6 A). The user has to install an additional fuse of 10 A trig-
ger current as back-up fuse.
Connection data:
Value
Input voltage
100 - 240 V AC (50/60 Hz)
120 - 370 V DC
Rated current
1.1 A
5.5.2 Electrical connection - central vacuum unit
The power connection is connected to the frequency converter.