Quick Start Guide
Operation of the AirSmart controller is easy. Simply select a Target Pressure and then press the Run
button to start the compressor, no other settings are required. The Target Pressure comes
preset to 100 PSI from the factory. The Unload Pressure is preset to 110 PSI. If a different pressure
setting is desired, the following steps can be used as a guide.
Setting the Target Pressure
The Target Pressure setting is used to set the operating point of the compressor. To make any
adjustments in the operation of the compressor, the machine must be stopped and in the Ready
mode. Stop the compressor by pressing the Stop/Reset
button. The front panel display
should read
“READY” on line 3.
Next, press the Enter
button to access the Adjustment Menu tree
Since the Target Pressure setting is under the Operation Adjustment menu, press Enter
again to access that sub-menu
The Target Pressure is the second item in the Operation Adjustment sub-menu so press the Down
button to navigate to the Target Pressure setting.
0 PSI 75°F
10 HRS AUTOMATIC
READY
NO SERVICE ADVISORY
ADJUSTMENT MENU
OPERATION ADJUSTMENT
(SELECT SUB MENU)
OPERATION ADJUSTMENT
LANGUAGE-LANGUAGE
ENGLISH (US)
(SELECT PARAMETER)
OPERATION ADJUSTMENT
TARGET PRESSURE
100 PSI
(SELECT PARAMETER)