13-21-602 Page 26
The compressor starts and stops automatically. Automatic restarting can
cause injury or death. Open, lockout and tagout main disconnect and any other
circuits before servicing the unit.
STARTING THE UNIT
- Observe the following starting procedures.
Unit Cold
- If the unit is a water-cooled heat exchanger model, open any manual water inlet valves wide
open. Start the unit by pushing either the “CONSTANT RUN” button or one of the “AUTO” buttons. Since
the unit is equipped with a minimum (65 psig, 4.5 bar) pressure discharge valve, no special procedure to
maintain unit reservoir pressure is required.
Unit Hot
- No warm-up period is required. If the unit is a water-cooled heat exchanger model, open any
manual water inlet valves wide open. Start the unit by pushing either the “CONSTANT RUN” button or
one of the “AUTO” buttons.
DAILY CHECK
- Refer to Section 8, “Maintenance Schedule,” page 72.
STOPPING THE UNIT
- Press “STOP-RESET” button. The oil reservoir will automatically blow down as
the motor stops. If the unit is a water-cooled heat exchanger type, close any manual water inlet valves.
Summary of Contents for EAQ99T
Page 13: ...13 21 602 Page 12 Figure 1 6 AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing...
Page 45: ...13 21 602 Page 44 Figure 4 14 WIRING DIAGRAM WYE DELTA 328EAQ546 A Ref Drawing Page 1 of 2...
Page 46: ...13 21 602 Page 45 328EAQ546 A Ref Drawing Page 2 of 2...
Page 47: ...13 21 602 Page 46 Figure 4 15 WIRING DIAGRAM LESS STARTER 330EAQ546 A Ref Drawing Page 1 of 2...
Page 48: ...13 21 602 Page 47 330EAQ546 A Ref Drawing Page 2 of 2...
Page 52: ...13 21 602 Page 51 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 203EDM797 A Ref Drawing...
Page 77: ......