13-10-615 Page 23
4.
Wipe lubrication fitting clean and add grease with a hand-operated grease gun. Only enough grease
should be added to replace the grease used by the bearing. Too much grease can be as harmful as
insufficient grease. The grease capacity should be about ½ full.
5.
Leave the relief plug temporarily off. Reconnect the unit and run for about 20 minutes to expel the
excess grease.
6.
Stop the unit. Replace the relief plug.
7.
Restart the unit.
Rotating machinery can cause injury or death. Open main disconnect, lockout
and tagout power supply to starter before working on the electric motor.
ELECTRIC MOTOR GREASE RECOMMENDATIONS (-30
°
C to 50
°
C)
MANUFACTURER TRADE
NAME
CHEVRON SRI
#2
SHELL DOLIUM
R
EXXON UNIREX
#2
EXXON POLYREX
ELECTRIC MOTOR REGREASING INTERVAL
Type of
Service
Typical
Rating
Relubrication Interval
Up to 150 HP (112 kW)
18 Months
Standard
One or Two Shift Operation
Above 150 HP (112 kW)
12 Months
Up to 150 HP (112 kW)
9 Months
Severe Continuous
Operation
Above 150 HP (112 kW)
6 Months
Up to 150 HP (112 kW)
4 Months
Very Severe
Dirty Locations, High Ambient
Temperature
Above 150 HP (112 kW)
2 Months