13-25-603 Page 68
SYMPTOM
POSSIBLE CAUSE
REMEDY
Oil carryover
1.
Overfilling oil separation
vessel.
1.
Drain excess oil from
system.
2.
Clogged oil return line
orifice.
2.
Inspect and service.
3.
Clogged, broken or loose
oil return line fittings.
3.
Inspect and tighten or
replace.
4.
Ruptured oil separator
element.
4.
Replace element.
5.
Loose assembly
5.
Tighten all fittings and
gaskets.
6.
Foam caused by use of
incorrect oil.
6.
Use Gardner Denver
AEON 4000 or AEON
9000SP oil only.
7.
Minimum pressure valve
malfunction – discharge
pressure below 65 psig
7.
Repair or replace. Inspect,
adjust or replace
regulator.