background image

Conduit Measuring Tape

JetLine

®

TT31 True Tape™ and ST40 Super True Tape™

provide an accurate means of measuring the  length of
conduit runs already in place. Both are marked in 
1' increments.

When measuring for wire length, measure from terminal to
terminal, not from end of conduit. See Conduit Measuring
Tape Table for allowances to be made for 90° bends, 45°
offsets, and panel boxes.

7.7 Seal-Offs

The GB/JetLine

®

seal-offs are the final connection between

the blower or Blo-Vac

hose and the conduit. Seal-offs

attach to the JV07 or B26 Dial-A-Line™ body. The tapered
seal-off cone (five sizes to fit 

1

2

" through 6" conduit) must be

held firmly in the conduit when blowing or vacuuming line
in conduit.

JV07 Dial-A-Line™ Body

The small JV07 Dial-A-Line™ body is used in conjunction
with the BV12 Hose Adapter, accepts the JV08 Short Seal-
Off, JV09 Long Seal-Off or the JV12 Seal-Off. The perforated
dial plate on the JV07 is adjusted to feed pull line up to 

1

8

"

diameter or for feeding TT31 True Tape™. Close off the feed
port when Power Saver™ or Tag-Along™ line packages are
used or when vacuuming.

JV08 Short Seal-Off

The JV08 Seal-Off is used in close quarters such as 2' x 4'
electrical boxes, etc. It may be used on 

1

2

" through

1

1

4

" conduit.

JV09 Long Seal-Off

The JV09 Seal-Off is similar to the JV08, except for length,
and is used to reach conduit in deep electrical boxes.

JV12 Seal-Off

The JV12 Seal-Off fits conduit sizes 1

1

4

" through 2

1

2

".

B26 Dial-A-Line™ Body

The B26 is a large seal-off body that can be coupled directly
to either the 1

1

2

" or 2

1

2

" hose assembly. It is used with the

BV23 and BV24 seal-offs. The dial plate has a small hole for
feeding pull line up to 

1

8

" diameter. The large hole is for larger

pull line and rope up to 

1

2

" diameter. The slot is for feeding

TT31 True Tape™ or the feed port may be closed off when
using a Tag-Along™ line package with line carrier or 
when vacuuming.

6

Figure 9. Conduit Measuring Tape

Conduit Measuring Tape

Part #

Description

Length

TT31

True Tape™

3000' roll

ST40

Super True Tape™

2750' roll

Figure 10. Dial-A-Line™ Seal-Off Body

and Hose Adapter

Figure 11. JV08 Short Seal-Off

Figure 12. JV09 Long Seal-Off

Figure 13. JV12 Seal-Off

Figure 14. Dial-A-Line™ Seal-Off Body

Summary of Contents for JetLine B4500K

Page 1: ...ND PROTECTION In setting up systems to fit your operations care must be taken to select the proper components and design to insure appropriate that all safety measures have been taken to avoid the ris...

Page 2: ...vicing CAUTION To reduce the risk of electrical shock Do not expose to rain Store indoors CAUTION Use only as described in this manual Use only manufacturer s recommended attachments WARNING Do not us...

Page 3: ...ccurs making it difficult to maintain pressure or vacuum to place a line in the conduit Blower Systems GB JetLine supplies two blower systems the B4500K Line Shooter for fishing from 1 2 through 4 tra...

Page 4: ...There are some conduit runs that will be difficult or impossible to blow a line in such as Conduit containing hard packed sand silt debris or concrete Conduit containing water with a head greater than...

Page 5: ...ing These lines are made of strong polyolefin plastic that will not rust rot or mildew The coreless wound roll of knot free pull line makes center dispensing from the carton a convenient feature when...

Page 6: ...he feed port when Power Saver or Tag Along line packages are used or when vacuuming JV08 Short Seal Off The JV08 Seal Off is used in close quarters such as 2 x 4 electrical boxes etc It may be used on...

Page 7: ...local obstructions that would stop a foam line carrier In large conduit 4 5 and 6 the Inflatables may lie against the conduit wall It may be necessary to point the seal off nozzle toward the inflatabl...

Page 8: ...conduit Tag Along Line Package Tag Along line packages perform the same function as Power Saver line packages except they are used in 11 4 diameter and larger conduit Tag Along package must be used w...

Page 9: ...e line carrier to prevent loss of the line in the conduit 5 Insert the line carrier in the conduit and hold the seal off firmly in the conduit entrance and turn on the blower Vacuuming Pull Line in th...

Page 10: ...an the filter bag by shaking off the excess dirt and store the clean bag in the lower compartment 4 The Blo Vac is equipped with a ball float to prevent water from entering the motor If the ball float...

Page 11: ...ly 1 8 lbs 3 BR 1060 1 Heavy duty Hose 11 2 dia 9 lb 4 BR 1003 Long Seal off for 1 2 1 conduit 4 lb 5 BR 1004 Seal off for 11 4 11 2 conduit 1 3 lbs 6 BR 1005 Seal off for 2 4 conduit 1 2 lbs 7 BR 165...

Page 12: ...prepaid PARTS AND SERVICE For quality workmanship and genuine Gardner Bender parts select an Authorized GB Service Center for your repair needs Only repairs performed by an Authorized Service Center...

Reviews: