SPECIFICATIONS

Batteries:

 CAM-10 Use 2 LR44 button cell batteries

Operating Range:

 50-600 VAC, 50-60 Hz

Voltage Indicators:

 Audible & Visual Alert

Storage Temperature:

 0°F (-18°C) to  156°F (70°C) 

Operating Temperature:

 32-122°F (0-50°C)

Humidity:

 80% RH maximum below 86˚F(30˚C),

    50% RH maximum above 86°F (30°C)

Altitude:

 Up to 6561 feet (2000 meters)

Safety:

 For indoor use and in accordance with over 

    voltage category III, Pollution degree 2

Intended Use:

 Non-contact AC voltage detection

Serial No:

 See interior of battery cover

CLEANING

Use clean, dry cloth. Do not use any type of solvent. 

BEFORE USE

READ ALL OPERATING INSTRUCTIONS BEFORE USE. FOR 
INTENDED USE ONLY.

 Protection provided by this product 

may be impaired if used with accessories not provided by the 

manufacture or if used as in a manner other than specified within.

WARNING:

 To be used by trained person only. High voltage AC

and DC circuits are dangerous. Use extreme caution and use as

intended when testing potentially live circuits. Risk of Electrocution.

WARNING:

 This product should be used to test or detect insulated 

wires and terminals but should not be used to contact Live Circuits.

This tester will not detect voltage in wires that are electrically

shielded by metal conduit or grounded enclosures. Risk 

of Electrocution. 

OPERATION

Before use, test the batteries of the CAM-10 tester by pressing 

the button on the tester marked PRESS. A momentary audible 

tone and flash of the light are an indication that the unit is working.  

WARNING:

 Always test on known live circuit before use.

To test for voltage:

1. Hold the wire stripper with your thumb

on the CAM-10 tester button

marked PRESS, keeping hands

and fingers well away

from the sensor (red end).

2. Press down and hold the

test button on the tester. 

A momentary alert indicates

the unit is working.

3. Place the sensor (red end) near the wire

or device to be tested. Maintain a

minimum distance of 0.5mm from

contacting the wire or device to be tested.

If voltage greater than 50 VAC is present,

the tester light and tone will activate rhythmically at

10 to 15 cycles second.

To detach the tester

 from the wire stripper, apply force to the 

tester near the Gardner Bender logo and slide the tester from 

the holding slot. The tester can be used to test for voltage after 

it is detached per instructions within. Hold the tester as shown, 

keeping hands and fingers well away from the sensor (red end).

CAM-10 BATTERY REPLACEMENT

Remove the Phillips

®

 head screw from the bottom of the CAM-10 

tester. Lift off the battery cover from the top of the tester. Insert 

2 LR44 batteries in the orientation indicated on the side of the 

battery cover. Replace cover and screw.

ESPECIFICACIONES

Baterías:

 El modelo CAM-10 usa 2 baterías de botón LR44

Rango operativo: 

50-600 VCA, 50-60 Hz

Indicadores de voltaje:

 Alerta sonora y visual

Temperatura operativa: 

0-50°C

Humedad: 

80% HR máxima, 50% HR máxima sobre 30°C

Altitud:

 Hasta 2000 metros.

Seguridad: 

Para uso en interiores y conforme a la categoría III 

    de sobrevoltaje

    Grado de contaminación 2. IEC 529, IEC 1010

Uso previsto: 

Detección de voltaje CA sin contacto

LIMPIEZA

Use un paño limpio y seco. No use ningún tipo de solvente. 

ANTES DEL USO

LEA TODAS LAS INSTRUCCIONES OPERATIVAS ANTES DEL 
USO.  SÓLO PARA EL USO PREVISTO.

ADVERTENCIA: 

Son peligrosos los circuitos de CA y CC de 

alto voltaje. Tenga sumo cuidado y utilice de la manera prevista 

al probar circuitos potencialmente energizados. Riesgo de 

electrocución.

ADVERTENCIA: 

Este probador no detecta el voltaje en cables 

que tienen blindaje eléctrico mediante portacables de metal o 

cierres puestos a tierra. Riesgo de electrocución.

OPERACIÓN

Antes de usar, pruebe las baterías del probador CAM-10 

oprimiendo el botón en el probador que está marcado PRESS. 

Un tono audible momentáneo y un destello de luz 

son indicaciones de que la unidad está funcionando.  

ADVERTENCIA: 

Siempre pruebe en un circuito energizado 

conocido antes de usar.

Para probar el voltaje:

1. Sostenga los peladores de cables con el

pulgar en el botón del probador CAM-10

marcado PRESS, manteniendo las

manos y los dedos bien alejados

del sensor (extremo rojo).

2. Oprima y mantenga así el botón

de prueba en el probador. Una

Limited Lifetime Warranty limited solely to repair or replacement; no warranty or 

merchantability or fitness for a particular purpose. Product is warrantied to be free 

of defects in materials and workmanship for the normal life of the product. In no 

event shall Gardner Bender be liable for incidental or consequential damage.

GST-55M, GST-224M, GST-70M

Wire Strippers

CAM-10

Non-contact Voltage Tester

Patents Pending

GST-55M, GST-224M, GST-70M

Peladores de cables 

CAM-10

Probador de voltaje sin cantacto

INSTRUCCIONES

OPERATIVAS

Patentes pendientes

SYMBOLS

This equipment has double insulation with respect to live circuits
Attention, consult the accompanying documents

!

!

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com