Instructions

Electrical Hook-up

Hushh-Pumps
(

PE22J / PE24J Series Models)

Plug in unit, use 115 volt AC grounded power source. (Unit
arrives wired for 115 volt operation.) See pump nameplate
for pertinent electrical requirements. (Motor rotation must
be counterclockwise looking down at shroud.) Motor is
wired this way at factory.

Hushh-Pumps

(PE34J / PE34R

30 Series, 40 Series and 50 Series Models)

1. Check motor voltage on motor nameplate (located on

side of motor housing). When shipped from factory,
single phase, 110/220 volt, 60 cycle motors are wired
for 110 volts. Three phase, 208/220/440 volt, 60 cycle
motors have accessible motor leads under shroud.
Motor rotation must be clockwise.

2. Plug cord into proper electrical outlet or provide 

wiring as required. To rewire single phase motors for
200 volts or three phase motors for 440 volts, see
diagram on motor nameplate, or under motor cover.
Have only qualified electrical personnel complete the
necessary wiring.

SPECIFICATIONS

AND INSTRUCTIONS

WARNING:

  

READ ALL PERTINENT INSTRUCTIONS 

BEFORE OPERATING HIGH VOLTAGE AND ROTATING 
PARTS CAN CAUSE SERIOUS OR FATAL INJURY 
INSTALLATION.  OPERATION AND MAINTENANCE OF 
ELECTRICAL MACHINERY SHOULD BE PERFORMED 
BY QUALIFIED PERSONNEL MAKE SURE THAT THE 
MOTOR AND EQUIPMENT ARE GROUNDED AND 
PROTECTED IN ACCORDANCE WITH THE NATIONAL 
ELECTRIC AND LOCAL CODES SEE NEMA  MG-2 
SAFETY STANDARDS.

CAUTION: 

BEFORE STARTING PUMP. OPEN AIR VENT 

VALVE MAINTAIN OIL TEMPERATURE BELOW 130˚F 
USE ENERPAC OIL OVERLOAD PROTECTION 
FACTORY SET FOR 10,000 PSI OPERATION.

MOTOR SPECIFICATIONS

VOLTS SINGLE PHASE

SERVICE FACTOR

ELECTRIC

MANUAL

4-WAY

3-WAY

2-WAY

HP

HZ

AMPS

1

115/230

60

19/95

1.3

MODEL NO

SERIAL NO

PUMP SPECIFICATIONS

USABLE OIL CAP –– 190 CU. IN

RATED DELIVERY

 CU. IN./MIN.      330    240       42

         P.S.I.           0      500    10,000

VALVE:

CA416 026

ENERPAC, BUTLER, WISCONSIN U.S.A. DIVISION OF APPLIED POWER INC.

ENERPAC, BUTLER, WISCONSIN U.S.A. DIVISION OF APPLIED POWER INC.

®

SPECIFICATIONS

AND INSTRUCTIONS

®

HP

SERVICE FACTOR

MOTOR CONNECTED

1.5

60

HZ

1.2

PHASE

SINGLE

115

230

GALLONS

2

5

10

460

THREE

VOLTS

CIRCUIT REQUIRED

PUMP DUTY CYCLE

CONTINUOUS

MODEL NO

SERIAL NO

RATED DELIVERY

USABLE OIL CAPACITY

ON FIVE MINS

INTERMITTENT – 50% BASED

15

20

30   AMPS

10,000     

P.S.I.

 8,000      

P.S.I.

PUMP SPECIFICATIONS

  CU. IN/MIN.        

720          500          62

             P.S.I.          

0            400       10,000

VALVE

MANUAL

ELECTRIC

TYPE

2-WAY

4-WAY

DUMP

3-WAY

MOTOR SPECIFICATIONS:

WARNING: 

READ ALL INSTRUCTIONS BEFORE OPERATING. HIGH VOLTAGE 

AND ROTATING PARTS CAN CAUSE AND INJURY. INSTALLATION AND 
MAINTENANCE OF ELECTRICAL MACHINERY MUST BE ERFORMED BY 
QUALIFIED PERSONNEL. MAKE SURE THE MOTOR AND EQUIPMENT ARE 
GROUNDED AND PROTECTED IN ACCORDANCE WITH THE NATIONAL 
ELECTRIC AND LOCAL CODES. SEE NEMA MG-2 SAFETY STANDARD.

CAUTION: 

BEFORE STARTING PUMP, OPEN AIR VENT VALVE. MAINTAIN OIL 

TEMPERATURE BELOW 130˚F. USE ENERPAC OIL. RELIEF VALVE IS SET AT 
10,000 P.S.I. OPERATION FOR OVERLOAD PROTECTION.

G532 026

Installing Gauge

1. Screw the gauge adaptor into valve port

(

3

8

" NPT).

2. A shut-off valve is recommended when using

a hydraulic gauge.

3. Screw gauge into gauge adaptor.
4. Make sure connections are tight. If necessary

seal threaded connections with pipe dope or
teflon tape.

Hose Connection

1. Screw 

3

8

" NPT hose end into gauge adaptor.

2. Connect hose half of high-flow coupler to cylinder

half of coupler (furnished with all GB cylinders).

3. Tighten both connections.

NOTE

: Make sure couplers are wiped clean

when making or breaking a connection.
High-flow coupler halves seal themselves
against oil leakage when disconnected.
Dust caps should be attached to prevent
dirt from entering exposed ends of high-
flow coupler when disconnected.

Gauge

Hose

Gauge

Adaptor

Remove

Plug