4
5
1
Heat twisted copper with Butane Gas
Torch* and apply solder (A).
Solder should fully penetrate all
strands (B).
Trim solder with side cutters and
carefully remove any sharp edges (C).
Repeat for other cable join.
Place Adhesive Lined End Cap** over
soldered join.
Ensure 1/3 (minimum) of cap length
overlaps PVC insulation (A).
Apply heat gently to end cap. Cap will
collapse and encapsulate the join (B).
Adhesive should be visible from the
base of the cap.
Repeat for other cable join.
Reconnect IP67 connector (A).
Coil cable neatly into cut-out
cavity (B).
Insert fitting into cavity (C).
*
Butane Gas Torch and solder available from Gardens at Night.
**
Adhesive Lined End Caps are available in various sizes to suit different low voltage cable sizes.
Caps should be at least 1/3 larger than join and are available from Gardens at Night.
3
FITTING INSTALLATION INSTRUCTIONS — RECESSED
Solder
1/3
3
Fan out all exposed copper
strands (A).
Tightly twist red fitting, feed and exiting
cable (B), ensuring shoulders of PVC
insulation remain aligned.
Repeat for black cables.