8. Technical Data
Min. / max. operating pressure :
1 bar / 12 bar
Flow medium :
Clean fresh water
Max. water temperature :
40 °C
Number of program-controlled watering cycles
per day:
Up to 3
Watering cycles per week :
Every day, every 2nd, 3rd or 7th day
Watering time per program :
1, 3, 5, 7, 10, 15, 20, 25, 30, 45, 60, 75, 90,
120, 150 or 180 minutes
Battery:
1 x 9 V alkali-manganese (alkaline)
type IEC 6LR61
Running time :
Approx. 1 year
Disposing of flat batteries :
Storage / Wintering :
6. Trouble-Shooting
Fault Possible
cause
Remedy
Not able to open the
Battery capacity too low
v
Insert a new alkaline
Water Timer manually
(3 LED s flash).
battery.
using “ON / OFF”.
Tap turned off.
v
Turn on tap.
Watering not initiated.
Control knob turned to
v
Turn the control knob to
“Frequency” or “ON / OFF”.
“Run Time Minutes”.
Battery capacity too low
v
Insert a new alkaline
3 LEDs flash).
battery.
Data input / changes made
v
Input data or make changes
while the program was starting
before or after the starting
or immediately before.
times you have chosen.
Tap turned off.
v
Turn on tap.
Battery flat after working
The battery you inserted
v
Use an alkaline battery.
for a short time.
is not an alkaline battery.
If you have any other problems with your Water Timer, please contact GARDENA Service.