Gardena V3 Operating Instructions Manual Download Page 2

8

EN

Intended use 

Control Technology  of
Watering Valves 

GARDENA Valve Box V 1 / V 3 

Translation of the original instructions from German. 
Please read these operating instructions carefully and observe the notes given. 
Use these operating instructions to familiarise yourself with the Valve Box, its proper 
use and the notes on safety. 

A

For safety reasons, children and young people under 16 years of age as well as people

               who are not familiar with these operating instructions should not use this Valve Box. 
               Persons with reduced physical or mental abilities may use the product only if they are
               supervised or instructed by a responsible person. Children must be supervised to ensure 
               that they do not play with the product. Never operate the product when you are tired, ill or 
               under the influence of alcohol, drugs or medicine. 

v

 

Please keep these operating instructions in a safe place. 

1.  Where to Use Your GARDENA Valve Box 

. . . . . . . . . . . . . . . . . . . . . . 

8

2.  Safety Precautions

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

8

3.  Assembly

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

9

4.  Operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

11

5.  Putting out of operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

11

6.  Trouble-Shooting 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

12

7.  Accessories

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

12

8.  Technical Data

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

12

9.  Service / Warranty 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

13

1. Where to Use Your GARDENA Valve Box 

The Valve Boxes are intended for installing GARDENA Watering
Valves underground. 

The watering system can be controlled in the following ways: 

Watering Valve Art. 1251 (9 V): 

Direct valve programming with the 

Programming Unit Art. 

1242

is ideal for decentralised valve installation with 

Controller 

Art. 1250

Watering Valve Art. 1278 (24 V)*: 

Up to 12 Watering Valves can be controlled via cables using the

Watering Controller 4040 Art. 1276 / Expansion Module 2040
Art. 1277

and the 

Connection Cable Art. 1280

* Only available on selected markets. 

You must read and comply with the Operating Instructions 
provided by GARDENA to ensure that you use the Valve Box 
properly. 

2. Safety Precautions

V

 

Read the notes on safety in the Valve Box 

V

Before the frost period starts : see point 5. Putting out of
operation “Winter storage”. 

v

 

Please observe the notes on safety in the operating 
instructions.

Contents

Winter Storage

Summary of Contents for V3

Page 1: ...nstructies voor gebruik Ventielbox SV Bruksanvisning Ventildosa DA Brugsanvisning Ventilboksen NO Bruksanvisning Automatisk ventil IT Istruzioni per l uso Pozzetto per valvole ES Manual de instruccion...

Page 2: ...alve Box 8 2 Safety Precautions 8 3 Assembly 9 4 Operation 11 5 Putting out of operation 11 6 Trouble Shooting 12 7 Accessories 12 8 Technical Data 12 9 Service Warranty 13 1 Where to Use Your GARDENA...

Page 3: ...be closed The adjacent earth may only be carefully compacted to prevent the walls getting pressed in and the lid from then no longer closing completely If necessary support walls from inside with spac...

Page 4: ...o the outlet side of the Irrigation Valve C 5 Insert the securing clip 9 into the holes of the distributor out puts 0 and the connections 7 The telescopic pipes 8 B are fixed in place When you open th...

Page 5: ...g out of operation The following precautions must be taken especially before the frost period starts to prevent damage to the Irrigation Valves and the entire watering system 1 Close the water tap and...

Page 6: ...in v Turn Watering Valve in close constant flow of opposite direction to flow the box observe the water direction direction of the water flow Selector lever K set to v Set selector lever K to ON posit...

Page 7: ...ve the right to choose between these options This service is subject to the following provisions The product was used for its intended purpose as per the recommendations in the operating instructions...

Page 8: ...e sachet en poly thyl ne peut entra ner un risque d touffement Veuillez maintenir les enfants distance lors du montage NL Gevaar Deze machine genereert een elektromagnetisch veld tijdens het gebruik D...

Page 9: ...ykkeligt at vi ikke p tager os noget ansvar for skader p vores produkter hvis de p g ldende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brug...

Page 10: ...dena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development Ko...

Reviews: