background image

GB

F

NL

PL

GR

SL

O

HR

GARDENA

®

GB

Operating Instructions

Water Timer 

F

Mode d’emploi 

Programmateur nez de robinet 

NL

Gebruiksaanwijzing 

Watertimer 

PL

Instrukcja obsіugi 

Sterownik nawadniania 

GR

Οδηγίες χρήσης 

Προγραμματιστή Ποτίσματος

SLO

Navodila za uporabo 

Ura za zalivanje 

HR

Uputstva za upotrebu

Mjeraи vremena za 
navodnjavanje 

T 1030 card  Art. 1830 

Summary of Contents for T 1030

Page 1: ...d emploi Programmateur nez de robinet NL Gebruiksaanwijzing Watertimer PL Instrukcja obsіugi Sterownik nawadniania GR Οδηγίες χρήσης Προγραμματιστή Ποτίσματος SLO Navodila za uporabo Ura za zalivanje HR Uputstva za upotrebu Mjeraи vremena za navodnjavanje T 1030 card Art 1830 ...

Page 2: ...ung people under 16 as well as anyone who is not familiar with these operating instructions may not use the Water Timer Persons with reduced physical or mental abilities may use the product only if they are supervised or instructed by a responsible person v Please keep these operating instructions in a safe place 1 Where to Use Your GARDENA Water Timer 3 2 For Your Safety 3 3 Function 4 4 Putting ...

Page 3: ...ganese alkaline batter ies may be used The Water Timer will only run for approx 1 year if the new alkaline batteries has a nominal voltage of at least 1 5 V v Have the batteries checked before purchase 1 Where to Use Your GARDENA Water Timer The GARDENA Water Timer is intended for private use in domestic and hobby gardens exclusively for outdoor use to control sprinklers and irrigation systems The...

Page 4: ...ly the control unit can be removed for program ming The max temperature for the water is 40 C v Only use clear fresh water 3 Function The GARDENA Water Timer allows you to set different watering cycles for different watering times independent of whether you are using a sprinkler a sprinkler system installation or drip head water ing system to irrigate your garden Your Water Timer will water your g...

Page 5: ...old the programming card 2 Red LED Indicates a fault 3 Green LED Indicates the system is operating 4 Red button Start reading in the program Manual operation 5 Storage For storing the programming card compartment 5 2 3 4 1 ...

Page 6: ... a self test The valve is closed automati cally during this process Make sure you exchange the batteries at the right time to prevent the Water Timer failing due to low batteries when you are away for longer periods of time Make sure that the time the batteries have been in operation and the time you are planning to be away does not add up to more than 1 year Even if the batteries are almost empty...

Page 7: ... a 26 5 mm G thread Connecting the Water Timer to taps with a 33 3 mm G1 thread 1 Screw the sleeve nut 4 of the Water Timer onto the thread of the tap by hand do not use pliers 2 Screw the threaded tap connector 6 onto the Water Timer Connecting the Water Timer to taps with a 26 5 mm G thread 1 Screw the adapter 5 onto the tap by hand do not use pliers 2 Screw the sleeve nut 4 of the Water Timer o...

Page 8: ...red area or place rain sensor with extension cable if necessary outside the watered area 2 Insert the sensor in the sensor connection 7 of the Water Computer 5 Operating Your Water Timer The time of day and the watering starting time are set to the near est hour One of the following 6 watering cycles can be selected 8 hours 8h 12 hours 12h 24 hours 24h 2 days 2D 3 days 3D or 7 days 7D The watering...

Page 9: ...sh cycle slide to the cycle required e g 24 hours every day 2 Insert programming card 8 in the card slot of the Water Timer 3 Press red button briefly The green LED flashes for 10 seconds 4 Remove programming card 8 at a constant speed whilst keeping it straight within 10 seconds The green LED goes on for 5 seconds and the program has been transferred If the green LED flashes at 10 second interval...

Page 10: ...et On rainy days the programmed watering cycle is often unneces sary You can therefore stop the programmed watering cycle bad weather function The program set is retained on the pro gramming card in this case Manual watering remains possible 1 Push watering cycle slide to prog off 2 Transfer program see Programming the Water Timer To reactivate the program set previously the watering cycle set pre...

Page 11: ...on the not in an unambiguous position programming card Both LEDs are flashing Battery level is too low v Insert new alkaline batteries Opening manually impossible Valve is blocked 1 Remove batteries 2 Remove blockage and clean filter Watering has not been Water tap off v Turn tap on initiated Sensor active shows there v See instructions for is sufficient moisture the sensor Battery flat after work...

Page 12: ... your local waste recycling centre Only dispose of batteries when they are flat 8 Technical Data Min max operating pressure 0 bar 12 bar Flow medium Clean fresh water Max water temperature 40 C Number of program controlled watering cycles per day Up to 3 8h 2 12h Watering cycles per week Every day 24h every 2nd day 2D 3rd day 3D 7th day 7D Watering time per program 1 3 5 7 10 15 20 25 30 45 60 75 ...

Page 13: ... the purchaser or a non authorised third party have attempted to repair the unit Faults which occur as a result of incorrectly installed or leaking batteries are not covered by the guarantee This manufacturer s guarantee does not affect the user s existing warranty claims against the dealer seller If you have any problems with your Water Timer please con tact our Customer Service or return the def...

Page 14: ... pour tout ajout de pièces et d accessoires autres que ceux préconisés par GARDENA N Productaansprakelijkheid Wij wijzen er nadrukkelijk op dat wij op grond van de wet aansprakelijkheid voor producten niet aansprakelijk zijn voor schade ontstaan door onze apparaten indien deze door onvakkundige reparatie veroorzaakt zijn of er bij het uitwisselen van onderdelen geen gebruik gemaakt werd van onze o...

Page 15: ... bevestigt dat het volgende genoemde apparaat in de door ons in de handel gebrachte uitvoering voldoet aan de eis van en in overeenstemming is met de EU richtlijnen de EU veiligheidsstandaard en de voor het product specifieke stan daard Bij een niet met ons afgestemde verandering aan het apparaat verliest deze verklaring haar geldigheid p Deklaracja zgodnoњci Unii Europejskiej Niїej podpisany GARD...

Page 16: ...tives Year of CE marking Directives européennes Date d apposition du marquage CE EU richtlijnen 89 336 EC Installatiejaar van de CE aanduiding Dyrektywy UE Rok nadania znaku CE 2004 Προδιαγραφές ΕΚ 93 68 EC Έτος πιστοποιητικού ποι τητας CE Smernice EU Leto pridobitve CE oznake Smjernice EU Godina oznake CE Peter Lameli Ulm 01 08 2004 Technical Dept Manager Fait à Ulm le 01 08 2004 Direction techni...

Page 17: ...os Colegios Moravia 200 metros al Sur del Colegio Saint Francis San José Phone 506 297 68 83 exim_euro racsa co cr Croatia KLIS d o o Stanciceva 79 10419 Vukovina Phone 385 1 622 777 0 gardena klis trgovina hr Cyprus FARMOKIPIKI LTD P O Box 7098 74 Digeni Akrita Ave 1641 Nicosia Phone 357 22 75 47 62 condam spidernet com cy Czech Republic GARDENA spol s r o Tuшanka 115 627 00 Brno Phone 420 548 21...

Page 18: ...ortugal Lda Sintra Business Park Edifício 1 Fracção 0 G 2710 089 Sintra Phone 351 21 922 85 30 info gardena pt Romania MADEX INTERNATIONAL SRL Soseaua Odaii 117 123 Sector 1 Bucureєti RO 013603 Phone 40 21 352 76 03 madex ines ro Russia ООО ГАРДЕНА РУС 123007 г Москва Хорошевское шоссе д 32А Тел 7 495 380 31 92 info gardena rus ru Singapore Hy Ray PRIVATE LIMITED 40 Jalan Pemimpin 02 08 Tat Ann Bu...

Reviews: