IMPORTANT!
v
Dispose of the product through or via your municipal recycling
collection centre.
6. TROUBLESHOOTING
DANGER! Risk of injury!
Injury when the product starts accidentally.
v
Disconnect the product from the mains before you trouble-
shoot the product.
To loosen the impeller [ Fig. T1 ]:
An impeller blocked by dirt can be freed again.
v
Turn shaft of the impeller
(10)
with a screwdriver.
This will loosen the stuck impeller.
Problem
Possible Cause
Remedy
Pump is running, but the
suction action doesn’t take
place
Leaky or damaged suction
hose.
v
Check suction line for
damage and seal so is
airtight.
The pump was not filled with
water.
v
Fill the pump
(see 3. OPERATION).
The liquid escapes over the
hose which is connected to
the delivery side during the
suction action.
v
1. Fill the pump again
(see 3. OPERATION).
2. When starting operation
hold the pressure hose
approx. 1 m vertically
above the pump, until the
suction action has taken
place.
Absolutely vacuum-resistant connection is achieved by using
GARDENA Suction Hoses (see 8. ACCESSORIES).
Leaky screw fitting at the filler
neck.
v
Check seal (replace if neces-
sary) and tighten connection
securely (do not use pliers).
Air cannot escape, since
delivery side is closed or
remaining water is in the
pressure hose.
v
Open shut-off valves
(e g. nozzle) in the delivery
line, empty the delivery hose
or disconnect it from the
pump during priming.
The waiting time wasn’t
observed.
v
Switch on the pump and wait
up to 5 min.
Suction filter or backflow
preventer in the suction hose
clogged.
v
Clean the filter or the back
flow preventer.
Too high suction height.
v
Reduce suction height.
In case of any other difficulties concerning the suction action,
use GARDENA Suction Hoses with Backflow Preventer
(see 8. ACCESSORIES) and fill in the liquid to be pumped
over the filler neck before operation.
Pump does not start,
or stops suddenly during
operation
Thermal switch has turned
the pump off because of over-
heating.
v
Observe the max. media
temperature (35 °C).
No power supply to the pump.
v
Check fuses and electrical
plug connections.
RCD has triggered
(residual current).
v
Disconnect the pump
and contact the GARDENA
Service.
Pump is not switched on.
v
Push the On / Off switch
to On.
Pump is running but the
delivery drops suddenly
Suction hose end is not
in water.
v
Submerge the end of the suc-
tion hose deeper in the water.
Suction filter or backflow
preventer clogged.
v
Clean the suction filter or
back-flow preventer.
Leaks at suction side.
v
Eliminate leak.
Impeller blocked.
v
Release impeller.
Noise development in the
hydraulic area
In the case of strong flows (e.g. open hose end, without connec-
ting device), noise may result in the hydraulic part of the pump.
This is harmless and does not lead to damage of the pump.
The noise can be removed by lightly changing the flow (e. g. light
opening / closing of a connecting device).
NOTE: For any other malfunctions please contact the GARDENA service
department. Repairs must only be done by GARDENA service departments
or specialist dealers approved by GARDENA.
7. TECHNICAL DATA
Garden Pump
Unit
Value
(Art. 9010)
Value
(Art. 9013)
Rated power
W
600
800
Mains voltage
V (AC)
230
230
Mains frequency
Hz
50
50
Max. delivery capacity
l/h
3000
3600
Max. pressure /
max. delivery head
bar /
m
3.5 /
35
4.0 /
40
Max. self-priming suction
height
m
7
7
Permitted internal pressure
(delivery side)
bar
6
6
Power cable
m
1.5 (H07RN-F)
1.5 (H07RN-F)
Weight
kg
5.3
8.2
Sound power level L
WA
1)
measured / guaranteed
Uncertainty k
WA
2)
dB(A)
77 / 80
3
71 / 73
2.2
Max. media temperature
°C
35
35
Measuring process complying with:
1)
RL 2000/14/EU
2)
ISO 4871
8. ACCESSORIES
GARDENA Suction Hoses
Kink-proof and vacuum-proof, optionally available by the metre
Art. 1720 / 1721 (19 mm (3/4")- / 25 mm (1")) without connecting
fittings or in fixed length Art. 1411 / 1418 complete with connecting
fittings.
GARDENA Suction Hose
Fitting
For connection on the suction side.
Art. 1723 / 1724
GARDENA Pump
Connection Set
For connection on the delivery side.
Art. 1750 / 1752
GARDENA Suction Filter
with backflow preventer
To equip suction hoses with backflow
preventer sold by the metre.
Art.
1726 / 1727 / 1728
GARDENA Pump
Preliminary-Filter
Recommended for pumping sandy liquids.
Art. 1730 / 1731
GARDENA Electronic
Manometric Switch
Automatically cuts in and out the pump
depending on the current operating pressure.
With dry-running safety.
Art. 1739
GARDENA Bore Hole
Suction Hose
For vacuum-resistant connection of the pump
to boreholes or pipe networks. Length 0.5 m.
With 33.3 mm (G1) female thread at both ends.
Art. 1729
GARDENA Floating suction
system
For dirt-free suction below the water surface.
Art. 1417
GARDENA Pump
Connection Piece
For connecting the GARDENA Connection
System on the pressure side.
Art. 1745
9. SERVICE / WARRANTY
Service:
Please contact the address on the back page.
Warranty statement:
In the event of a warranty claim, no charge is levied to you for the
services provided.
GARDENA Manufacturing GmbH grants a warranty for all original
GARDENA new products for two years from the date of original purchase
from the retailer, provided that the devices have been for private use only.
This manufacturer’s warranty does not apply to products acquired second
hand. This warranty includes all significant defects of the product that can
be proved to be material or manufacturing faults. This war ranty is fulfilled
by supplying a fully functional replacement product or by repairing the
faulty product sent to us free of charge; we reserve the right to choose
between these options. This service is subject to the following provisions:
• The product has been used for its intended purpose as per the
recommendations in the operating instructions.
• Neither the purchaser nor a third party has attempted to open or
repair the product.
• Only Original GARDENA replacement parts and wear parts have been
used for operation.
• Presentation of the receipt.
6
EN