background image

14

GB

direction matches the required irrigation limits. If watering in 
a complete circle, the two sector stops

z

L

and

z

R

must be

completely pushed together between P1 and P10. 

Anti-vandal device : 

If the nozzle head is violently turned over the sector-stops then
the vandalism protection is triggered. As soon as the water
supply is open, the sprinkler moves in one direction until the set
sector has been achieved again. 

The watering sector has to be selected before programming.
Up to 50 contour points can be programmed with the large-
area pop-up irrigation. The more points that are programmed,
the more precisely the contour will be described (e.g. with a
circular arc P7 – P10).

1. Open the two locks 

A

and raise the cover 

B

2. Open water supply. 

When using for the first time, the minimum range (2.5 m with 
a flow pressure of 2 bar at the sprinkler) is selected. 

3. Press 

OK

button 

4

The green Auto LED

6

lights up. 

4. Press 

Menu

button 

1

The red Set LED

5

lights up. 

5. Turn the nozzle head 

0

on the orange ring 

by hand

to the

left-hand sector limit (in the example P1) and hold.

6. Use the two buttons 

“+”

button 

2

and 

“-”

button 

3

to set 

the range so that it reaches P1. 

7. Press 

OK

button 

4

The green Auto LED 

6

lights up for 1 second and the first

point P1 has been stored. 

8. Turn the nozzle head 

0

on the orange ring 

by hand

to the

next irrigation point (e.g. P2) and hold. 

9. Use the two buttons 

“+”

button 

2

and 

“-”

button 

3

to set 

the range so that it reaches P2 for example. 

10. Press 

OK

button 

4

The green Auto LED 

6

lights up for 1 second and the point

has been stored. 

11. Repeat the process from step 8 to 10 until the right-hand 

sector limit is reached (in the example P10). 

12. Press 

Menu

button 

1

The red Set LED 

5

goes out,

programming is complete, and

the green Auto LED 

6

lights up for 1 minute. The red Set LED

then flashes every 8 seconds. 

13. Release nozzle head 

0

and check contour area watered.

14. If the contour is watered correctly, close the water supply. 

15. Close cover 

B

and both locks 

A

Information about programming : 

As soon as the first point is programmed, any existing 
programme will be deleted. After programming has been
completed, no further points can be deleted or added later on. 
If the contour has not been set as required, reprogramming 
with more points will have to be carried out. If no button is 
pressed for 60 seconds during programming, programming 
will be automatically ended and the contour stored. 

Programme contour points 
of irrigation sector :

2

4

3

1

6

5

A

B

0

Summary of Contents for AquaContour automatic 1559

Page 1: ...nstructies voor gebruik Verzonken multi instelbare sproeier S Bruksanvisning AquaContour automatic Pop up I Istruzioni per l uso Irrigatore Pop up per superfici irregolari E Manual de instrucciones Aspersor emergente de múltiples superficies P Instruções de manejo Aspersores embutidos de grandes superfícies DK Brugsanvisning AquaContour automatic Pop up AquaContour automatic Art 1559 ...

Page 2: ... Operation 13 6 Putting into Storage 15 7 Maintenance 15 8 Troubleshooting 16 9 Accessories 17 10 Technical Data 18 11 Service Warranty 18 1 Where to use Your GARDENA Large Area Pop Up Irrigation The GARDENA Large Area Pop Up Irrigation forms part of the GARDENA Irrigation System and is designed to be used solely outdoors in domestic and private gardens to water lawns and garden areas It is not pe...

Page 3: ...LED Indicates programming mode 6 Auto LED Indicates automatic operating mode The LED flashes every 10 seconds 4 Initial Operation Correct location A Circle water distribution With circle water distribution the large area pop up irrigation should be positioned as centrally as possible in the watering area to ensure that the irrigation width is not greatly affected by external influences such as win...

Page 4: ...st set up and check whether the large area pop up irrigation can water the required area see 5 Operation 2 If the large area pop up irrigation has watered the required area in the test install a pack of coarse gravel 9 approx 20 cm x 20 cm x 20 cm in size underneath the unit This ensures proper functioning of the drain valve 3 Install the upper edge of the large area pop up irrigation level with t...

Page 5: ...so that it reaches P1 7 Press OK button 4 The green Auto LED 6 lights up for 1 second and the first point P1 has been stored 8 Turn the nozzle head 0 on the orange ring by hand to the next irrigation point e g P2 and hold 9 Use the two buttons button 2 and button 3 to set the range so that it reaches P2 for example 10 Press OK button 4 The green Auto LED 6 lights up for 1 second and the point has ...

Page 6: ...2 Close water supply The large area pop up irrigation is automatically emptied via the built in drain valve The product must not be added to normal household waste It must be disposed of in line with local environmental regulations v Important Make sure that the unit is disposed of via your municipal recycling collection centre The large area pop up irrigation contains lithium ion cells that shoul...

Page 7: ...oiled v Clean dirt filter on initial start up Tap not opened sufficiently v Open tap further Water pressure too low v Increase water pressure water supply Rechargeable batteries almost v Ensure solar cells are flat Auto and Set LED flashing exposed to sufficient Protective panel of solar cells sunlight clean protective soiled panel If the rechargeable battery is almost flat the range is reduced to...

Page 8: ...ter For automatic watering control Art 1825 1830 1835 1860 1862 1864 1866 1874 GARDENA L piece For connection to below ground Art 2781 water supply GARDENA Connecting For below ground installation Art 2700 2701 2718 Pipe 25 mm of water supply GARDENA Connector For below ground installation Art 2761 of water supply GARDENA Connecting Point For below ground installation Art 2722 of water supply GARD...

Page 9: ...f the unit that can be proved to be material or manufacturing faults Under warranty we will either replace the unit or repair it free of charge if the following conditions apply The unit must have been handled properly and in keeping with the requirements of the operating instructions Neither the purchaser or a non authorised third party have attempted to repair the unit As a wear part the dirt fi...

Page 10: ...en om skadan beror på att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra än Original GARDENA reservdelar har använts Samma sak gäller för kompletteringsdelar och tillbehör I Responsabilità Si rende espressamente noto che conformemente alla legislazione sulla del prodotto responsabilità del prodotto non si risponde di danni causati da nostri arti coli se originati da...

Page 11: ...ux directives européennes Le constructeur soussigné Husqvarna AB 561 82 Huskvarna Sweden déclare qu à la sortie de ses usines le matériel neuf désigné ci dessous était conforme aux prescriptions des directives européennes énoncées ci après et conforme aux règles de sécurité et autres règles qui lui sont applicables dans le cadre de l Union européenne Toute modification portée sur ce produit sans l...

Page 12: ... Tunguhalsi 1 110 Reykjavik ooj ojk is Ireland Husqvarna UK Ltd Preston Road Aycliffe Industrial Park Newton Aycliffe County Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia S p A Via Como 72 23868 VALMADRERA LC Phone 39 0341 203 111 info gardenaitalia it Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo Chiyoda ku Tokyo 102 0084 Phone 81 33 264 47...