Pollution of the liquid could occur due to leakage of lubricants.

Circuit breaker
Thermal protection switch: 

In the event of an overload, the pump is switched off by the built-in thermal motor 

protection. After sufficient cooling of the motor, the pump is operational again.

Additional safety warnings
Electrical safety

  

DANGER! Cardiac arrest!

This product makes an electromagnetic field while it operates. This  

field may under some conditions interfere with active or passive medical 

implants. To decrease the risk of conditions that can possibly injure or 

kill, we recommend persons with medical implants to speak with their 

physician and the medical implant manufacturer before you operate the 

product.

Cables
If extension cables are used, these must comply with the minimum cross- 

sections in the table below:

Voltage

Cable length

Cross section

230 – 240 V / 50 Hz

Up to 20 m

1.5 mm

2

230 – 240 V / 50 Hz

20 – 50 m

2.5 mm

2

 DANGER! Electric shock!

 

Risk of injury due to electric current.

v

  Disconnect the product from the mains before you put it into storage, 

maintain or troubleshoot.

The pump must be located on solid, even ground, protected from flooding. Take 

care that the pump cannot fall into water. Position the pump at a safe distance 

(min. 2 m) from the liquid to be pumped. As an additional safety device an 

authorised safety switch can be used.

v

  Please ask your electrician for his advice.

If the supply cord is damaged, it must be replaced by the manufacturer, its 

 service agent or similarly qualified persons in order to avoid a hazard. 
Protect the mains plug and the mains power cable from heat, oil and sharp 

edges.
Do not use the power cable for carrying the pump or for unplugging.
Protect the pump from rain. Don’t use the pump in wet or moist areas.
Please regularly check the connecting line.
Before using, always subject the pump (especially the power cables and the 

power connections) to a visual inspection.
A pump which is damaged must not be used. In the event of damage, have the 

pump checked by GARDENA Service.
When using our pumps with a generator, the warnings of the generator manufac-

turer must be observed.

Personal safety

  

DANGER! Risk of suffocation!

Small parts can be easily swallowed. There is also a risk that the poly-

bag can suffocate toddlers. Keep toddlers away when you assemble the 

product.

  

DANGER! Risk of injury due to hot water!

If the pump is operated for prolonged periods of time (> 5 min.) with the 

delivery side closed, the water in the pump may heat up so that there is 

a risk of scalding yourself with hot water.

v

  The pump should not run against the closed delivery side for more 

than 5 minutes.

If the water supply on the intake side of the pump fails, the water in the 

pump can heat up so that if water emerges, injuries could be caused by 

the hot water.

v

  Disconnect the pump from the mains via the main circuit breaker,  

let the water cool and secure the suction-side water supply before 

putting into operation again.

When connecting the pump to the water supply system, the country-specific 

sanitary regulations must be observed to prevent water not of drinking water 

 quality being drawn back in.

v

  Please consult a specialist for sanitary installations.

In order to avoid dry-running of the pump, take care that the end of the suction 

hose is always submerged into the liquid.

v

  Before each operation, fill the pump to overflowing with approx. 2 to 3 l of the 

liquid to be pumped!

Sand and other abrasive substances cause increased wear and reduce the 

pump’s output.

v

  Use a pump pre-filter for pumping sandy liquids.

Pumping dirty water, e.g. stones, pine needles etc., can cause damage to the 

pump.

v

  Do not pump dirty water.

2. ASSEMBLY

  

 DANGER! Risk of injury!

 

Injury when the product starts accidentally.

v  

Disconnect the product from the mains before you assemble 

the product.

To set up the pump:
The site must be firm and solid in order to ensure safe and sturdy operat-

ing conditions for the pump.

v

 Position the pump at a safe distance (min. 2 m) from the water.

The pump must be installed in a location with low air humidity and suffi-

cient ventilation in the area of the ventilation slots. It must be at a distance 

of at least 5 cm from the walls. Dirt (e. g. sand or soil) must not be sucked 

in through the ventilation slots.
The plastic connection pieces on the intake and delivery sides may 

only be tightened by hand.

To connect the hose to the suction side [ Fig. A1 ]:
Don’t use any hose quick connection system fittings on the suction side!

v

 A vacuum-resistant suction hose must be used, e. g. GARDENA 

 Suction  Unit,  Art. 1411 or GARDENA Bore Hole Suction Hose  

Art. 1729.

In order to reduce the suction time, it is advisable to use a suction hose 

with backflow preventer avoiding automatic draining of the suction hose 

when the pump has been switched off.
1. Screw the pump connection piece 

(2)

 into the connector on the suction 

side 

(1)

.

2. Connect the vacuum-resistant suction hose 

(3)

 airtight to the pump 

connection piece 

(2)

 of the pump.

3. For suction heights exceeding 4 m: Also fix the suction hose 

(3)

  

(e. g. by fastening it to a wooden post).  

This relieves the pump of the weight of the suction hose.

To connect the hose to the pressure side [ Fig. A2 ]:
The pump connection 

(4)

 is equipped with a 33.3 mm (G 1") internal 

thread.
E. g. a GARDENA pump connection piece Art. 1745 is required for  

the GARDENA Connection System (included in scope of delivery).
19 mm (3/4") / 16 mm (5/8") and 13 mm (1/2") hoses can be connected  

via the GARDENA Connection System.
Hose diameter

Pump connection

13 mm (1/2")

GARDENA Pump Connection Set

Art. 1750

16 mm (5/8")

GARDENA Tap Connector 
GARDENA Hose Connector

Art. 18202
Art. 18216

19 mm (3/4")

GARDENA Pump Connection Set

Art. 1752

Optimised use of the pump capacity is achieved by connecting  

19 mm (3/4") hoses with e. g. 
–   GARDENA Pump Connection Set Art. 1752, 
or by connecting 25 mm (1") hoses with 
–   GARDENA Quick Thread Coupling with external thread Art.  7115 /  

Quick Coupling Hose Connector Art. 7103.

1. Only for Art. 9014: Use sealing tape 

(P)

 on the external thread of the 

pump connection piece.

2. Screw the pump connection piece 

(2)

 into the connector on the delivery 

side 

(4)

.

3. Connect the pressure hose 

(5)

 to the pump connection piece 

(2)

.

If more than one hose /accessory is connected simultaneously, we 

 recommend using the 
–   GARDENA 2- or 4-Channel Water Distributor Art.  8193 / 8194,   

GARDENA Twin-Tap Connector Art. 940 

which can be screwed directly onto the pump connection piece 

(2)

.

3. OPERATION

  

 DANGER! Risk of injury!

 

Injury when the product starts accidentally.

Summary of Contents for 9010

Page 1: ...EN Operator s manual Garden Pump GP 3000 4 Art 9010 GP 3700 4 Art 9014 EN ...

Page 2: ...ci GARDENA albo części autoryzowanych przez tę firmę HU Termékszavatosság A németországi termékszavatossági törvénnyel összhangban ezennel nyomatékosan kijelentjük hogy nem vállalunk felelősséget a termékeinkben keletkezett olyan károkért amelyek valamely GARDENA által jóváhagyott szervizpartner által nem megfelelően végzett javításból adódtak vagy amely során nem eredeti GARDENA alkatrészeket vag...

Page 3: ...3 3 A1 3 2 1 A2 2 4 N 5 2 4 N 5 Art 9010 Art 9014 O1 6 5 7 O2 min 1 m 8 5 S1 6 5 7 9 T1 7 0 ...

Page 4: ...essure boosting the maximum permissible internal pressure of 6 bar on the delivery side must not be exceeded The increased delivery pressure and the pump pressure have to be added together Example Pressure at the tap 2 5 bar max pressure of the Garden Pump Art 9010 3 5 bar total pressure 6 0 bar The product is not intended for long term use continuous circulation operation DANGER Risk of injury v ...

Page 5: ... Please consult a specialist for sanitary installations In order to avoid dry running of the pump take care that the end of the suction hose is always submerged into the liquid v Before each operation fill the pump to overflowing with approx 2 to 3 l of the liquid to be pumped Sand and other abrasive substances cause increased wear and reduce the pump s output v Use a pump pre filter for pumping s...

Page 6: ...ct starts accidentally v Disconnect the product from the mains before you trouble shoot the product To loosen the impeller Fig T1 An impeller blocked by dirt can be freed again v Turn shaft of the impeller 10 with a screwdriver This will loosen the stuck impeller Problem Possible Cause Remedy Pump is running but the suction action doesn t take place Leaky or damaged suction hose v Check suction li...

Page 7: ... warranty claim no charge is levied to you for the services provided GARDENA Manufacturing GmbH grants a warranty for all original GARDENA new products for two years from the date of original purchase from the retailer provided that the devices have been for private use only This manufacturer s warranty does not apply to products acquired second hand This warranty includes all significant defects ...

Page 8: ...rakteristiky čerpadla Χαρακτηριστικό διάγραμμα Характеристика насоса Karakteristika črpalka Obilježja pumpe Karakteristika pumpe Крива характеристики насоса Caracteristică pompă Pompa karakter eğrisi Помпена характеристика Fuqia e pompës Pumba karakteristik Siurblio charakteristinė kreivė Sūkņa raksturlīkne max 2 900 l h max 7 m 5 m max 2 600 l h 10 m max 1 650 l h max 700 l h 20 m 30 m max 35 m m...

Page 9: ...paratet apparaterne der ikke er aftalt med os mister denne erklæring sin gyldighed FI EU vaatimustenmukaisuusvakuutus Allekirjoittanut vahvistaa valmistajan GARDENA Germany AB PO Box 7454 S 103 92 Tukholma Ruotsi valtuuttamana hen kilönä että seuraava laite täyttää seuraavat laitteet täyttävät meidän toimittamassa mallissa yhdenmukaistettujen EU direktiivien EU turvallisuusmääräysten ja tuotekohta...

Page 10: ...unty Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan Husqvarna Zenoah Co Ltd 1 9 Minamidai Kawagoe 350 1165 Saitama gardena jp husqvarnagroup com Kazakhstan LAMED Ltd 155 1 Tazhibayevoi Str 050060 Almaty IP Schmidt Abayavenue 3B 110 005 Kostanay Korea Kyung Jin Trading C...

Reviews: