background image

14

15

GB

GB

2. For Your  Safety 

V

Read the notes on safety on the Petrol-driven Motor Pump.

The silencer and exhaust system become very hot during 
operation and remain hot for some time after turning off 
the motor.

V

Do not touch the silencer and exhaust system when hot.

Petrol is combustible and explosive under certain conditions.

V

Do not smoke or work with naked flames or sparks when
pouring petrol into the fuel tank of your pump or in places
where petrol is stored.

V

Keep all flammable substances (such a petrol) and flam-
mable objects away from the pump during operation.

V

Do not overfill the fuel tank when filling your pump with
petrol.

V

Close the fuel tank securely after filling your pump with
petrol.

V

Wipe off any spilt petrol completely before starting the
motor.

V

Do not stand anything on the motor. This could cause 
a fire.

Exhaust emissions contain poisonous carbon monoxide.

V

Do not breathe in exhaust emissions.

V

Never operate the pump in a closed room.

If you operate your pump for longer periods of time (> 5 min)
against the closed delivery side of the pump the water in the
pump may heat up. There is a risk of injury from hot water
scalding you.

V

Do not operate the pump for more than 5 minutes against
the closed delivery side of the pump.

V

Turn off the pump immediately if the liquid fails to flow.

Allowing the pump to run dry increases the wear and should be
avoided.

v

Switch off the pump immediately after all the liquid has been
pumped.

Sand and other abrasive materials in the liquid you are pumping
cause increased wear and reduce the performance of the pump.

v

Never operate the pump without the air filter.
(This causes the motor to wear more quickly).

v

To prevent corrosion after pumping saltwater rinse the pump
immediately with clean fresh water.

The minimum flow rate is 80 l / h (= 1.3 l / min). Do not connect
equipment with a lower flow rate.

When using the pump to increase water pressure, ensure that 
the inner pressure does not exceed the maximum permissible
inner pressure of 6 bar (delivery side of the pump).
Add together the water output pressure you want to increase 
and the pump pressure.

Example :

Pressure at the tap 2 bar. Pump pressure 3.5 bar.

Total pressure 5.5 bar.

Caution ! 
Risk of fire 
and explosion 

Caution ! 
Risk of 
suffocation

Risk of injury from scalding
yourself with hot water 

Notes on use :

Intended use 

Please note 

GARDENA Petrol-driven Motor Pump 8000 / 4 4 T

Welcome to the Garden of GARDENA...

Please read and follow these operating instructions carefully.
Use these instructions to use the Petrol-driven Motor Pump cor-
rectly and observe the safety information.

For safety reasons, children under 16 as well as persons not
familiar with these operating instructions must not use the
Petrol-driven Motor Pump.

v

Please keep these operating instructions in a safe place.

1. Where to use Your GARDENA Petrol-driven Motor Pump

. . . 

14

2. For Your Safety

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

15

3. Putting Into Operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

16

4. Operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

16

5. Maintenance

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

18

6. Trouble-Shooting

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

21

7. Putting Out of Operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

22

8. Accessories 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

22

9. Technical Data

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

23

10. Service 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

23

1. Where to Use Your GARDENA Petrol-driven Motor Pump 

The GARDENA Petrol-driven Motor Pump is designed for private
use around the house and garden and is not intended for operat-
ing watering equipment or irrigation systems in public gardens.

The GARDENA Petrol-driven Motor Pump can also be used for
draining swimming pools, distributing water-soluble fertilisers and
pesticides, or for pumping lime paints and water-soluble wood 
preservatives.

The GARDENA Petrol-driven Motor Pump is not designed
for continuous operation (e.g. industrial applications, con-
tinuous circulating operation).

Do not use your GARDENA Petrol-driven Motor Pump to
pump corrosive, easily combustible, aggressive, or explo-
sive substances (such as petroleum, or nitro thinner),
or food.

The temperature of the liquid pumped must not exceed
35 °C.

Contents 

www.devicemanuals.eu

Summary of Contents for 8000/4 4T

Page 1: ...p F Mode d emploi Pompe thermique pour arrosage NL Gebruiksaanwijzing Benzinemotorpomp S Bruksanvisning Pump med bensinmotor I Istruzioni per l uso Motopompa E Manual de instrucciones Bomba a motor de gasolina P Instruções de utilização Bomba com motor a gasolina DK Brugsanvisning Benzindreven pumpe w w w d e v i c e m a n u a l s e u ...

Page 2: ... a lower flow rate When using the pump to increase water pressure ensure that the inner pressure does not exceed the maximum permissible inner pressure of 6 bar delivery side of the pump Add together the water output pressure you want to increase and the pump pressure Example Pressure at the tap 2 bar Pump pressure 3 5 bar Total pressure 5 5 bar Caution Risk of fire and explosion Caution Risk of s...

Page 3: ...nel Water Distributor Art 1210 1194 v Screw the Twin Tap Connector or Four Channel Water Distri butor directly onto the thread of the delivery connection 4 4 Operation 1 Set up the pump with the motor turned off 2 Check the oil level see 5 Maintenance 3 Check the petrol level see 5 Maintenance 4 Check the air filter see 5 Maintenance Connect the suction hose Connect the delivery hose Connecting se...

Page 4: ...tor Maintenance plan Only use oils labelled SE or SF 1 Unscrew the oil dipstick D from the oil filler neck E pull out and wipe clean 2 Insert the oil dipstick D into the oil filler neck E do not screw in and remove again 3 If there is no oil on the oil dipstick D pour in oil 4 Select the appropriate oil from the table according to the aver age ambient temperature 5 Pour in oil up to the upper edge...

Page 5: ...ting V Always turn off the motor and unplug the spark plug connector before trouble shooting If the turbine clogs it must be cleaned 1 Unscrew the 6 bolts O in the housing cover P using an open end spanner size 10 2 Remove the housing cover P 3 Clean the turbine 4 Mount the housing cover P in the reverse order Disassembly of the hydraulic unit other than removing the hous ing cover must only be ca...

Page 6: ...1730 GARDENA Bore Hole For vacuum resistant connection Suction Hose of the pump to boreholes or pipes Length 0 5 m With 33 3 mm G 1 female thread at both hose ends Art No 1729 Storage 9 Technical Data Petrol driven Motor Pump 8000 4 4 T Motor 4 stroke 1 1 kW 1 5 PS Tank volume 0 65 l normal petrol Max delivery capacity 8 000 l h Max pressure delivery head 3 5 bar 35 m Max suction height 7 5 m Max ...

Page 7: ...EN 809 Noise level measured 98 dB A guaranteed 101 dB A Year of CE marking 2002 Ulm 22 07 2002 Thomas Heinl Technical Dept Manager Product Liability If you have any problems with your pump please contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet We expressly po...

Page 8: ...szág Kft Késmárk utca 22 1158 Budapest Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Japan KAKUDAI Mfg Co Ltd 1 4 4 Itachibori Nishi ku Osaka 550 Luxembourg Magasins Jules Neuberg Grand Rue 30 Case Postale No 12 Luxembourg 2010 Netherland...