Intended use 

Liquids to be pumped 

Please note 

GARDENA Dirty Water Pump 
6500 SP / 8000 SP / 13000 SP 

Welcome to the garden of GARDENA ...

Translation of the original instructions from German.
Please read these operating instructions carefully and observe 
the notes given. Use the instructions to familiarise yourself with 
the dirty water pump, its correct use, and the notes on safety.

For safety reasons, children under 16 as well as persons not
familiar with these operating instructions should not use this
dirty water pump.

v

Keep these operating instructions in a safe place.

1. Applications Range of Your GARDENA Dirty Water Pump 

. . . . 

11

2. For Your Safety 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

12

3. Initial Operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

13

4. Operation 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

14

5. Cleaning 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

15

6. Trouble-Shooting 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

15

7. Storage

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

16

8. Technical Data 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

16

9. Service 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

17

1. Applications Range of Your GARDENA Dirty Water Pump 

GARDENA Dirty Water Pumps have been designed for private use
around your house and garden. They are predominantly destinated
for drainage after flooding, transfer of liquids, draining containers,
taking water from wells and shafts, draining boats and yachts as
well as for water aeration and circulation for a limited period of
time.

Liquids which can be handled by the GARDENA Dirty Water
Pumps are the following: clean and slightly contaminated water,
swimming pool water (prerequisite is the recommended dosage 
of additives) and soapy water.

GARDENA Dirty Water Pumps are able to convey dirty water con-
taining particles with a diameter of up to 25 mm (for model 6500 SP)
or 30 mm (for model 8000 SP / 13000 SP).

The pumps are fully submersible (waterproof sealed) and can be
submerged down to a depth of 9 m into the liquid.

The GARDENA Dirty Water Pumps are not designed for con-
tinuous operation (e.g. continuous circulating operation) in a
pond. Your pump’s life will be shortened correspondingly 
by such operation.
Corrosive, easily combustible or explosive substances 
(e.g. gasoline, petroleum, nitro thinner), fats, oils, salt-water
and waste water of toilets and urinals must not be pumped.
The temperature of the liquid handled should not exceed 35 °C.

Contents

Summary of Contents for 6500 SP

Page 1: ...on pour eaux charg es NL Instructies voor gebruik Vuilwaterpomp S Bruksanvisning Spillvattenpump I Istruzioni per l uso Pompa sommersa per acqua sporca E Manual de instrucciones Bomba para aguas sucia...

Page 2: ...antly destinated for drainage after flooding transfer of liquids draining containers taking water from wells and shafts draining boats and yachts as well as for water aeration and circulation for a li...

Page 3: ...ion than the rubber sheathed cables of the designation H05 RNF model 6500 SP and 8000 SP or H07 RNF model 13000 SP The cable length must be at least 10 m Data indicated on the type plate must match te...

Page 4: ...ts in the pump During this process air escapes through the vent bores 4 and air bubbles appear underwater This is not a defect of your pump but serves to deaerate the pump It may take several seconds...

Page 5: ...nd the water is pumped out The float switch 5 turns the pump off again as soon as the water level falls below the cut out height 1 Stand the pump on a firm surface or use a rope attached through the b...

Page 6: ...A Risk of injury due to electric shock V Disconnect the pump from the mains before clean ing the suction base and feed impeller 1 Unscrew the 6 Phillips screws 8 model 6500 SP 4 Phillips screws and p...

Page 7: ...ontact our Service 7 Storage Store the pump away from frost before the first frost sets in The product must not be added to normal household waste It must be disposed of in line with local environment...

Page 8: ...ed impeller is a wearing part and is not covered by the guarantee This manufacturer s guarantee does not affect the user s existing warranty claims against the dealer seller If you have any problems w...

Page 9: ...ery Directive 98 37 EC 1998 2006 42 EC 2006 Electromagnetic Compatibility 2004 108 EC Low Voltage Directive 2006 95 EC Directive 93 68 EC Harmonised European standards EN 292 1 Ulm 29 05 2001 EN 292 2...

Page 10: ...Reykjavik ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Phone 39 02 93 94 79 1 info gardenaitalia it...

Reviews: