Gardena 5500/5 inox Operator'S Manual Download Page 6

EN

8

IMPORTANT!

v  

Dispose of the product through or via your municipal recycling 

 collection  centre.

5. MAINTENANCE

Clean priming area [ Fig. M1 ]:

  

 DANGER! Electric shock!

 

There is a risk of injury from electric shocks.

V  

Disconnect the Deep Well Pump from the mains power supply 

before carrying out maintenance.

1.  Unscrew both screws 

0

 and remove the inlet filter 

q

.

2.  Clean priming area of the pump and inlet filter 

q

.

3.  Fix inlet filter 

q

 around the priming area again and screw tight with the 

two screws 

0

.

6. TROUBLESHOOTING

  

 DANGER! Electric shock!

 

There is a risk of injury from electric shocks.

V  

Before eliminating faults, disconnect the Deep Well Pump from 

the mains power supply.

Problem

Possible Cause

Remedy

Pump is running,  

but doesn’t deliver

Air cannot escape as the 

 pressure line is closed.

v

  Open pressure line  

(e. g. bent pressure hose).

Priming area blocked.

v

 

 Disconnect mains plug  

and clean priming area  

(see 

5. MAINTENANCE

).

When starting the pump,  

water height falls below the min. 

water level.

v

  

Immerse pump deeper 

(observe minimum water 

level: see 

8. TECHNICAL 

DATA

).

Non­return valve blocked.

v

  

Art. 1499:

 Contact GARDENA 

Service.

Pump doesn’t start or  

suddenly stops during  

operation

Thermal protection switch 

 switched pump off due to 

 overheating.

v

  

Disconnect mains plug  

and clean priming area  

(see 

5. MAINTENANCE

).

Observe max. media 

 temperature (35 °C).

Power supply interrupted.

v

  

Check fuses and electrical 

plug­in connections.

Dirt particles are trapped in 

 priming  area.

v

  

Disconnect mains plug  

and clean priming area  

(see 

5. MAINTENANCE

).

Pump runs, but output  

suddenly decreases

Priming area blocked.

v

  

Disconnect mains plug  

and clean priming area  

(see 

5. MAINTENANCE

).

For Art. 1499 only:

  

Lack of water: Dry run  

protection switched the  

pump off due to insufficient 

water level.

The pump is only operational 

when it is submerged at least 

15 cm.

v

  Submerge pump at least  

15 cm in water.

 NOTE: For any other malfunctions please contact the GARDENA service depart-

ment. Repairs must only be done by GARDENA service departments or specialist 

dealers approved by GARDENA.

7. ACCESSORIES

GARDENA Fitting

For optimum utilisation of the pumping  

capacity of the pump.

Art. 1723 / 1724

GARDENA Pump Connection 

Set

If the hose connection is to be detached 

 frequently.

Art. 1752

For Art. 1489 / 1492 only:  

GARDENA Dry-Running  

Safety *

Deactivates the pump automatically if  

the pumped medium fails to flow.

Art. 1741

For Art. 1489 / 1492 only: 

 GARDENA  Electronic 

 Manometric  Switch  *

With Dry­Running Safety. Ideal for converting  

a pump into a pressure tank unit.

Art. 1739

*  GARDENA Dry Running Safety / Electronic Manometric Switch must not be installed directly on the 

pump, as they must not be  submerged in the water.

8. TECHNICAL DATA

Deep Well Pump

Unit

Value (Art. 1489) Value (Art. 1492) Value (Art. 1499)

Rated Power

W

850

950

950

Max. delivery capacity

l/h

5,500 *

6,000 *

6,000 *

Max. pressure /  

Max. delivery height

bar / m

4.5 / 45

5.0 / 50

5.0 / 50

Max. submersion depth

m

19

19

19

Power cable

m

22 H07RN­F

22 H07RN­F

22 H07RN­F

Pump connection

mm (")

40 (1 1/4)  

female thread

40 (1 1/4)  

female thread

33 (1)  

female thread

Min. water level for  

operation(from the top  

edge of the filter)

cm

> 15

> 15

> 15

Weight without cable 

(approx.)

kg

7.5

8.25

9

Fastening rope

m

22

22

22

Casing diameter (max.)

mm

< 98

< 98

< 98

Max. media temperature

°C

35

35

35

Mains voltage /  

Mains frequency

V / Hz

220 – 240 / 50 220 – 240 / 50 220 – 240 / 50

* If used in a well pipe of 10 cm diameter, the max. delivery capacity is not reached.

9. SERVICE / WARRANTY

Service: 
Please contact the address on the back page.
Warranty:
In the event of a warranty claim, no charge is levied to you for the services 

provided.
GARDENA Manufacturing GmbH offers a two-year warranty (effective  

as of the date of purchase) for this product. This warranty includes all 

 significant defects of the product that can be proved to be material or 

manufacturing faults. This warranty is fulfilled by supplying a fully func-

tional replacement product or by repairing the faulty product sent to us  

free of charge; we reserve the right to choose between these options.  

This service is subject to the following provisions:
•  The product was used for its intended purpose as per the recommen-

dations in the operating instructions.

•  Neither the purchaser nor a third party has attempted to repair the 

 product.

This manufacturer’s warranty does not affect  warranty entitlements  

against  the  dealer / retailer.

If problems arise with this product, please contact our Service depart-

ment or send the defective product along with a brief description of the 

fault to GARDENA Manufacturing GmbH, making sure to have sufficiently 

covered any shipping costs and to have followed the relevant postage 

and packaging guidelines. A warranty claim must be accompanied by  

a copy of the proof of purchase.

Consumables:

The wear part turbine is excluded from the warranty.  

Pumps damaged by frost are excluded from the warranty.

FR

Summary of Contents for 5500/5 inox

Page 1: ...tszivatty CS N vod k obsluze erpadlo pro erp n vody z hlubok ch studn SK N vod na obsluhu erpadlo na erpanie vody z hlbok ch studn EL RU SL Navodilo za uporabo rpalka za globoke vodnjake HR Upute za u...

Page 2: ...dnie z niemieck ustaw o odpowiedzialno ci za produkt niniejszym wyra nie o wiadczamy e nie ponosimy adnej odpowiedzialno ci za szkody poniesione na skutek u ytkowania naszych produkt w w przypadku gdy...

Page 3: ...3 A1 2 1 2 A2 5 5 3 3 4 6 6 7 7 7 O1 50 cm 15 cm a b 9 6 8 Art 1499 Art 1489 Art 1492 M1 0 q...

Page 4: ...uipment and systems Liquids to be pumped The GARDENA Deep Well Pump may only be used to pump clear fresh water The pump is watertight and is submerged in water for max submersion depth see 8 TECHNICAL...

Page 5: ...onto the pump from below 2 Screw the foot 1 to the pump 2 with the two screws Connecting the hose Fig A2 The 40mm 1 1 4 internal thread Art 1499 33mm 1 female thread on the outlet of the Deep Well Pum...

Page 6: ...tomatically if the pumped medium fails to flow Art 1741 For Art 1489 1492 only GARDENA Electronic Manometric Switch With Dry Running Safety Ideal for converting a pump into a pressure tank unit Art 17...

Page 7: ...pompy Szivatty jellegg rbe Charakteristika erpadla Charakteristiky erpadla Karakteristika rpalka Obilje ja pumpe Karakteristika pumpe Caracteristic pomp Pompa karakter e risi Fuqia e pomp s Pumba kara...

Page 8: ...n bez n ho s hlasu EL GARDENA Germany AB PO Box 7454 S 103 92 Stockholm SL Izjava ES o skladnosti Spodaj podpisana GARDENA Germany AB PO Box 7454 S 103 92 Stockholm vedska s to izjavo potrjuje da je b...

Page 9: ...rdena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development K...

Reviews: