![Gardena 5500/5 inox Operator'S Manual Download Page 6](http://html1.mh-extra.com/html/gardena/5500-5-inox/5500-5-inox_operators-manual_3716077006.webp)
EN
8
IMPORTANT!
v
Dispose of the product through or via your municipal recycling
collection centre.
5. MAINTENANCE
Clean priming area [ Fig. M1 ]:
DANGER! Electric shock!
There is a risk of injury from electric shocks.
V
Disconnect the Deep Well Pump from the mains power supply
before carrying out maintenance.
1. Unscrew both screws
0
and remove the inlet filter
q
.
2. Clean priming area of the pump and inlet filter
q
.
3. Fix inlet filter
q
around the priming area again and screw tight with the
two screws
0
.
6. TROUBLESHOOTING
DANGER! Electric shock!
There is a risk of injury from electric shocks.
V
Before eliminating faults, disconnect the Deep Well Pump from
the mains power supply.
Problem
Possible Cause
Remedy
Pump is running,
but doesn’t deliver
Air cannot escape as the
pressure line is closed.
v
Open pressure line
(e. g. bent pressure hose).
Priming area blocked.
v
Disconnect mains plug
and clean priming area
(see
5. MAINTENANCE
).
When starting the pump,
water height falls below the min.
water level.
v
Immerse pump deeper
(observe minimum water
level: see
8. TECHNICAL
DATA
).
Nonreturn valve blocked.
v
Art. 1499:
Contact GARDENA
Service.
Pump doesn’t start or
suddenly stops during
operation
Thermal protection switch
switched pump off due to
overheating.
v
Disconnect mains plug
and clean priming area
(see
5. MAINTENANCE
).
Observe max. media
temperature (35 °C).
Power supply interrupted.
v
Check fuses and electrical
plugin connections.
Dirt particles are trapped in
priming area.
v
Disconnect mains plug
and clean priming area
(see
5. MAINTENANCE
).
Pump runs, but output
suddenly decreases
Priming area blocked.
v
Disconnect mains plug
and clean priming area
(see
5. MAINTENANCE
).
For Art. 1499 only:
Lack of water: Dry run
protection switched the
pump off due to insufficient
water level.
The pump is only operational
when it is submerged at least
15 cm.
v
Submerge pump at least
15 cm in water.
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.
7. ACCESSORIES
GARDENA Fitting
For optimum utilisation of the pumping
capacity of the pump.
Art. 1723 / 1724
GARDENA Pump Connection
Set
If the hose connection is to be detached
frequently.
Art. 1752
For Art. 1489 / 1492 only:
GARDENA Dry-Running
Safety *
Deactivates the pump automatically if
the pumped medium fails to flow.
Art. 1741
For Art. 1489 / 1492 only:
GARDENA Electronic
Manometric Switch *
With DryRunning Safety. Ideal for converting
a pump into a pressure tank unit.
Art. 1739
* GARDENA Dry Running Safety / Electronic Manometric Switch must not be installed directly on the
pump, as they must not be submerged in the water.
8. TECHNICAL DATA
Deep Well Pump
Unit
Value (Art. 1489) Value (Art. 1492) Value (Art. 1499)
Rated Power
W
850
950
950
Max. delivery capacity
l/h
5,500 *
6,000 *
6,000 *
Max. pressure /
Max. delivery height
bar / m
4.5 / 45
5.0 / 50
5.0 / 50
Max. submersion depth
m
19
19
19
Power cable
m
22 H07RNF
22 H07RNF
22 H07RNF
Pump connection
mm (")
40 (1 1/4)
female thread
40 (1 1/4)
female thread
33 (1)
female thread
Min. water level for
operation(from the top
edge of the filter)
cm
> 15
> 15
> 15
Weight without cable
(approx.)
kg
7.5
8.25
9
Fastening rope
m
22
22
22
Casing diameter (max.)
mm
< 98
< 98
< 98
Max. media temperature
°C
35
35
35
Mains voltage /
Mains frequency
V / Hz
220 – 240 / 50 220 – 240 / 50 220 – 240 / 50
* If used in a well pipe of 10 cm diameter, the max. delivery capacity is not reached.
9. SERVICE / WARRANTY
Service:
Please contact the address on the back page.
Warranty:
In the event of a warranty claim, no charge is levied to you for the services
provided.
GARDENA Manufacturing GmbH offers a two-year warranty (effective
as of the date of purchase) for this product. This warranty includes all
significant defects of the product that can be proved to be material or
manufacturing faults. This warranty is fulfilled by supplying a fully func-
tional replacement product or by repairing the faulty product sent to us
free of charge; we reserve the right to choose between these options.
This service is subject to the following provisions:
• The product was used for its intended purpose as per the recommen-
dations in the operating instructions.
• Neither the purchaser nor a third party has attempted to repair the
product.
This manufacturer’s warranty does not affect warranty entitlements
against the dealer / retailer.
If problems arise with this product, please contact our Service depart-
ment or send the defective product along with a brief description of the
fault to GARDENA Manufacturing GmbH, making sure to have sufficiently
covered any shipping costs and to have followed the relevant postage
and packaging guidelines. A warranty claim must be accompanied by
a copy of the proof of purchase.
Consumables:
The wear part turbine is excluded from the warranty.
Pumps damaged by frost are excluded from the warranty.
FR