background image

Complete solution:

a

  GARDENA Rain Water 

 Collection  Filter   

Art. No. 3820 / 3821

b

  GARDENA Connecting Set  

Art. No. 3815

c

  GARDENA Cover for Rain  

Water Tank  

Art. No. 3801 / 3805

d

  GARDENA Rain Water Tank 

Art. No. 3800 / 3804

e

  GARDENA Rain Water Tank 

Pump 

Art. No. 1740 / 1742

a

e

b

c

d

Use in shallow vessels:

If the Rain Water Tank Pump is used in a shallow vessel, e. g. to 

empty an inflatable children’s pool, the telescopic pipe can be 

removed and replaced by the GARDENA Threaded Tap Connector 

33.3 mm (G 1) – 

Art.  No.  2902 / 2802. The hose connection  

13 mm (1/2"), 16 mm (5/8") or 19 mm (3/4") is made using the 

 Original GARDENA System or GARDENA Profi “Maxi-Flow” 

 System threaded hose connectors.

Use in deep containers:

For deeper containers (up to max. 7 m), the pump can no longer 

be hung on the telescopic pipe. The pump must then be attached 

through a cord connected to the telescopic pipe and submersed 

into the container.

Operation of a Micro-Drip-

System:

The operation of a Micro-Drip-System is possible. Here, the maxi-

mum values stated in the accompanying manual of the Master 

Unit 2000 are reduced. With 

Art. No. 1742, at least 90 l/h must be 

taken as otherwise the leakage protection is activated.

4000/2 (Art. No. 1740):

Dry-Running Safety:

9

So that the pump automatically switches off when there is 

no liquid to pump, the Float Switch 

9

 must be able to freely 

move on the surface of the water.

Switch-off height:
If the water level (with the foot fitted) drops below the cut-out  

level, the float switch 

9

 automatically switches off the pump 

 (Dry-Running  Safety).
• Cut-out height with free float switch = approx. 25 cm.
• Cut-out height with float switch lock = approx. 13 cm.

Switch-on height:
When the water level has risen over the cut-in height,  

the Float Switch 

9

 automatically switches the pump on.

• Cut-in height with free float switch = approx. 57 cm.
• Cut-in height with float switch lock = approx. 35 cm.

13

GB

Summary of Contents for 4000/2 automatic 1742

Page 1: ... sudu SK Návod na obsluhu Čerpadlo do suda GR Οδηγίες χρήσης Αντλία συλλεκτών βρόχινου νερού RUS Инструкция по эксплуатации Насос для резервуаров с дождевой водой SLO Navodilo za uporabo Potopna črpalka za deževnico HR Upute za uporabu Pumpa za spremnike kišnice SRB Uputstvo za rad BIH Pumpa za rezervoare kišnice UA Інструкція з експлуатації Насос для резервуарів з дощовою водою RO Instrucţiuni de...

Page 2: ...ot be performed by children without supervision The use of this product by young people under the age of 16 is not recommended v Keep these operating instructions in a safe place Contents 1 Area of application of your GARDENA Rain Water Tank Pump 10 2 Safety Instructions 11 3 Assembly 12 4 Initial Operation 12 5 Storage 14 6 Maintenance 15 7 Trouble Shooting 15 8 Technical Data 16 9 Service Warran...

Page 3: ...e manufacturer or the manufacturer s aftersales service or a similarly qualified person to prevent any hazards Before using always subject the pump especially the power cables and the power connections to a visual inspection A pump which is damaged should not be used In the event of damage have the pump checked by GARDENA Service Safety Instructions Observe the minimum water level in accordance wi...

Page 4: ...the telescopic pipe 3 should be adjusted in such a manner that the pump does not touch the bottom of the con tainer this way dirt in the container is kept away from the pump 1 Pull telescopic pipe 3 from the side of the pump and screw onto the pump connector 4 Ensure that the washer lies in the mating thread ß 3a of the telescopic pipe 3 2 Loosen threaded collars 5 of the telescopic pipe 3 3 Adjus...

Page 5: ...ected to the telescopic pipe and submersed into the container Operation of a Micro Drip System The operation of a Micro Drip System is possible Here the maxi mum values stated in the accompanying manual of the Master Unit 2000 are reduced With Art No 1742 at least 90 l h must be taken as otherwise the leakage protection is activated 4000 2 Art No 1740 Dry Running Safety 9 So that the pump automati...

Page 6: ... operation again Leakage protection If there is leakage on the pressure side e g a leaking pressure hose or connecting device the pump automatically switches on and off in short intervals When the pump switches on and off more frequently than 7 x in 2 min with a leakage less than 90 l h the pump switches completely off When the leakage on the pressure side is eliminated the pump must be unplugged ...

Page 7: ...pressure line is closed Possible kink in the pressure hose v Open the pressure line e g shut off valve delivery units Air in suction foot v Wait for about max 60 seconds until the pump has vented if necessary turn off and then on again Foot Suction foot Filter is clogged v Unplug at the mains and clean filter see 6 Maintenance Water level below minimum water level when put into operation v Submerg...

Page 8: ... Hz 220 240 V AC 50 Hz 9 Service Warranty Warranty GARDENA guarantees this product for 2 years from date of purchase This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults Under warranty we will either replace the unit or repair it free of charge if the following conditions apply The unit must have been handled properly and in keeping with t...

Page 9: ... pompy Szivattyú jelleggörbe Charakteristika čerpadla Charakteristiky čerpadla Χαρακτηριστικό διάγραμμα Характеристика насоса Karakteristika črpalka Obilježja pumpe Karakteristika pumpe Крива характеристики насоса Caracteristică pompă Pompa karakter eğrisi Помпена характеристика Fuqia e pompës Pumba karakteristik Siurblio charakteristinė kreivė Sūkņa raksturlīkne 2 5 2 0 1 5 1 0 0 5 bar m 0 500 10...

Page 10: ...tet ud og der ikke er anvendt originale GARDENA dele eller dele godkendt af os eller hvis reparationerne ikke er udført af GARDENA service eller en autoriseret fagmand Det samme gælder for ekstra udstyr og tilbehør FI Tuotevastuu Korostamme nimenomaan että tuotevastuulain nojalla emme ole vastuussa laitteistamme johtuneista vahingoista mikäli nämä ovat aiheutuneet epäasianmukaisesta korjauksesta t...

Page 11: ...ele in opremo HR Odgovornost za proizvod Izričito napominjemo da u skladu sa Zakonom o odgovornosti za proizvode nismo odgovorni za štete uzrokovane našim uređajima ako su one izazvane nestručnim popravkom ili u slučaju zamjene dijelova nisu korišteni originalni GARDENA dijelovi ili dijelovi koje smo odobrili i popravak nije izvršio GARDENA servis ili ovlašteni stručnjak Isto vrijedi i za dodatne ...

Page 12: ...a zharm onizowanych dyrektyw Unii Europejskiej standardu bezpieczeństwa Unii Europejskiej i standardu specyficznego dla tego typu produktów W przypadku zmiany urządzenia która nie została z nami uzgodniona niniejsza deklaracja traci moc obowiązywania H EU Megfelelőségi nyilatkozat Alulírott a Husqvarna AB 561 82 Huskvarna Sweden igazolja azt hogy az alábbiakban megnevezett készülékek az általunk f...

Page 13: ...Colocación del distintivo CE Ano de marcação pela CE Rok nadania oznakowania CE CE jelzés elhelyezésének éve Rok umístění značky CE Rok udelenia značky CE Έτος σήματος CE Leto namestitve CE oznake Godina dobivanja CE oznake Anul de marcare CE Година на поставяне на CE маркировка CE märgistuse paigaldamise aasta Metai kada pažymėta CE ženklu CE marķējuma uzlikšanas gads 2010 Ulm den 29 01 2015 Ulm ...

Page 14: ...na husqvarna co uk Italy Husqvarna Italia S p A Via Como 72 23868 VALMADRERA LC Phone 39 0341 203 111 info gardenaitalia it Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo Chiyoda ku Tokyo 102 0084 Phone 81 33 264 4721 m_ishihara kaku ichi co jp Kazakhstan LAMED Ltd 155 1 Tazhibayevoi Str 050060 Almaty IP Schmidt Abayavenue 3B 110 005 Kostanay Korea Kyung Jin Trad...

Reviews: