background image

Circuit breakers
Dry-running protection: 

If the water level is too low, the pump switches off automatically.

v  

Submerge the pump deeper into the water.

Thermal protection switch: 

In the event of an overload, the pump is switched off by the built-in thermal motor 

protection. After sufficient cooling of the motor, the pump is operational again.

Automatic venting
This pump is equipped with a vent valve which eliminates any air pockets in the 

pump. Depending on the function, a small amount of water can escape below 

the handle.

Additional safety warnings
Electrical safety

  

DANGER! Cardiac arrest!

This product makes an electromagnetic field while it operates. This  

field may under some conditions interfere with active or passive medical 

implants. To decrease the risk of conditions that can possibly injure or 

kill, we recommend persons with medical implants to speak with their 

physician and the medical implant manufacturer before you operate the 

product.

Cables:
If extension cables are used, these must comply with the minimum cross- 

sections in the table below:

Voltage

Cable length

Cross section

230 – 240 V / 50 Hz

Up to 20 m

1.5 mm

2

230 – 240 V / 50 Hz

20 – 50 m

2.5 mm

2

  

DANGER! Electric shock!

With a cut off mains plug, moisture can get into electrical parts via the 

mains cable and cause a short circuit.

v

  Never cut the mains plug off (e. g. to feed through wall).

v

  Don’t use the power cable for plugging off.

v

  If the supply cord is damaged, it must be replaced by the manufacturer, its 

service agent or similarly qualified persons in order to avoid a hazard. 

Mains plug and extension connections must be protected from water splashes.
Ensure that the electrical connections for plugs and sockets are made in areas 

safe from flooding.
Protect the mains plug and the mains power cable from heat, oil and sharp 

edges.
Observe the mains voltage. The information on the nameplate must be in agree-

ment with the data for the mains power grid.
The pump’s mains plug must be disconnected before anybody enters the swim-

ming pool.
The mains power cable must not be used for fastening or transporting the pump. 
Submersion and withdrawal of the pump should be by means of the telescopic 

pipe. Alternatively, a cord can be secured on the pump for submersing, lifting and 

securing of the Rain Water Tank Pump.
Please regularly check the connecting line.
Before using, always subject the pump (especially the power cables and the 

power connections) to a visual inspection.
A pump which is damaged should not be used. In the event of damage, have  

the pump checked by GARDENA Service.
Do not disassemble the pump any further than the delivery condition.
Before use after maintenance, make sure that all parts are screwed together.
When using our pumps with a generator, the warnings of the generator manu-

facturer must be observed.

Personal safety

  

DANGER! Risk of suffocation!

Small parts can be easily swallowed. There is also a risk that the poly-

bag can suffocate toddlers. Keep toddlers away when you assemble the 

product.
Observe the minimum water level in accordance with the characteristics given for 

the pump.
Only for Art.  1762 / 1764: Allow the pump to run no longer than 10 minutes 

against a closed pressure side.
Sand and other abrasive substances cause increased wear and reduce the 

pump’s output.
The pump must not be operated without the filter.
The float switch may only be operated outside the water.
The hose must not be disconnected during operation.
Allow the pump to cool down before troubleshooting.

2. ASSEMBLY

  

 DANGER! Risk of injury!

 

Injury when the product starts accidentally.

v  

Disconnect the product from the mains before you assemble 

the product.

To assemble the telescopic pipe [ Fig. A1 ]:
We recommend the use of a GARDENA Hose Connector for connecting 

a garden hose:
–   Art. 18215 for 13 mm (1/2") and 16 mm (5/8") or
–   Art. 18216 for 19 mm (3/4"). With the use of 19-mm-(3/4")-hose line, 

the pumping quantity is the greatest.

The telescopic pipe can be adjusted between 38 – 55 cm. 
1. Only for Art. 1766: Screw the upper part of the telescopic pipe 

ß

1a

 

counterclockwise onto the lower part of the telescopic pipe 

ß

1b

.  

Make sure that the small washer 

ß

2a

 is located in the connecting  

thread of the lower part of the telescopic pipe 

ß

1b

.

2. Only for Art. 1762 / 1764: Put the float switch locking 

(A)

 on the pump 

connector 

(3)

.

3. Screw the telescopic pipe 

(1)

 onto the pump connector 

(3)

. Make  

sure that the big washer 

ß

2b

 is located in the connecting thread of the 

telescopic pipe 

(1)

.

4. Loosen the threaded collar 

(4)

 of the telescopic pipe 

(1)

.

5. Adjust the telescopic pipe 

(1)

 to the desired height and tighten the 

threaded collar 

(4)

 again.

6. Connect the garden hose to the telescopic pipe 

(1)

.

The telescopic pipe 

(1)

 is fitted with a GARDENA Shut-Off Valve 

(5)

.  

The shut-off valve 

(5)

 can also be used for fine adjustment of the pump 

performance.

3. OPERATION

  

 DANGER! Risk of injury!

 

Injury when the product starts accidentally.

v  

Disconnect the product from the mains before you connect, 

adjust or transport the product.

To pump water from a container [ Fig. O1 ]:
The length of the telescopic pipe 

(1)

 should be adjusted in such a manner 

that the pump does not touch the bottom of the container; this way, dirt in 

the container is kept away from the pump.
1. Hang the pump from the telescopic pipe 

(1)

 into the container.

2. If necessary, extend the telescopic tube 

(1)

 with a hose  

(see 8. ACCESSORIES).

3. Connect the pump to the mains.  

Attention! The pump begins operating immediately.

Applications:
In shallow vessels [ Fig. O2 ]:
If the rain water tank pump is placed in flat containers, e. g. to empty  

a paddling pool, the telescopic pipe can be removed and replaced with 

the 
–   GARDENA tap connector 33.3-mm (G 1) Art. 18202 / 18042 / 2602
The hose connection 13 mm (1/2"), 16 mm (5/8") or 19 mm (3/4") is made 

using the Original GARDENA System or GARDENA Profi “Maxi-Flow” 

 System threaded hose connectors.

In deep containers:
For deeper containers (up to max. 7 m), the pump can no longer be  

hung on the telescopic pipe. The pump must then be attached through  

a cord connected to the pump and submersed into the container.  

We  recommend to attach the hose to the pump without the telescopic 

tube.

Operation of a Micro-Drip-System:
The operation of a Micro-Drip-System is possible.
Only for Art. 1762: The pump is ideally suited for connection to  

a Micro-Drip-System without a Master Unit.
Only for Art. 1766: From 100 l/h the pump runs continuously.  

Below this, the pump frequently switches on and off and switches  

to the small quantity program.

EN

8

EN

Summary of Contents for 4000/1

Page 1: ... χρήσης Αντλία συλλεκτών βρόχινου νερού RU Инструкция по эксплуатации Насос для резервуаров с дождевой водой SL Navodilo za uporabo Potopna črpalka za deževnico HR Upute za uporabu Pumpa za spremnike kišnice SR Uputstvo za rad BS Pumpa za rezervoare kišnice UK Інструкція з експлуатації Насос для резервуарів з дощовою водою RO Instrucţiuni de utilizare Pompă pentru rezervor apă de ploaie TR Kullanm...

Page 2: ...i GARDENA albo części autoryzowanych przez tę firmę HU Termékszavatosság A németországi termékszavatossági törvénnyel összhangban ezennel nyomatékosan kijelentjük hogy nem vállalunk felelősséget a termékeinkben keletkezett olyan károkért amelyek valamely GARDENA által jóváhagyott szervizpartner által nem megfelelően végzett javításból adódtak vagy amely során nem eredeti GARDENA alkatrészeket vagy...

Page 3: ...3 A1 ß 1a ß 2a 4 1 ß 1b ß 2b 3 5 O3 6 O2 O1 1 O4 6 O5 6 M1 7 ...

Page 4: ...nated water in private domestic gardens and allotments The pump is completely submersible watertight encapsulation and is submerged in the water to a max depth of 7m The product is not intended for long term use continuous circulation operation DANGER Risk of injury The pump should not be used for the delivery of salt water muddy water corrosive easily inflammable or explosive liquids e g petrol p...

Page 5: ...pump to run no longer than 10 minutes against a closed pressure side Sand and other abrasive substances cause increased wear and reduce the pump s output The pump must not be operated without the filter The float switch may only be operated outside the water The hose must not be disconnected during operation Allow the pump to cool down before troubleshooting 2 ASSEMBLY DANGER Risk of injury Injury...

Page 6: ...witching off earlier when used with low quan tity of water e g drip irrigation the leakage warning is only activated after 60 minutes Switching the pump on and off cyclically during the low quantity program has no effect on the service life of the pump For continuous drip irrigation If the low quantity program is to be used for more than 60 minutes the irrigation must be disrupted for at least 5 m...

Page 7: ...ntact the address on the back page Warranty statement In the event of a warranty claim no charge is levied to you for the services provided GARDENA Manufacturing GmbH grants a warranty for all original GARDENA new products for two years from the date of original purchase from the retailer provided that the devices have been for private use only This manufacturer s warranty does not apply to produc...

Page 8: ...x 23 m max 3 700 l h 5 m max 2 850 l h 10 m max 1 900 l h 15 m 4000 1 Art 1762 4700 2 inox Art 1764 4700 2 inox automatic Art 1766 Características de performance Charakterystyka pompy Szivattyú jelleggörbe Charakteristika čerpadla Charakteristiky čerpadla Χαρακτηριστικό διάγραμμα Кривая производительности насоса Karakteristika črpalka Obilježja pumpe Karakteristika pumpe Крива характеристики насос...

Page 9: ...sten ja tuotekohtaisten standardien vaatimukset Laitteen laitteiden muutoksissa joista ei ole sovittu meidän kanssamme menettää tämä selvitys voimassaolonsa IT Dichiarazione di conformità UE Il sottoscritto in quanto soggetto autorizzato dal produttore GARDENA Germany AB PO Box 7454 S 103 92 Stoccolma Svezia dichiara che l apparecchio gli apparecchi di seguito denominato i nella versione da noi im...

Page 10: ... Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo Chiyoda ku Tokyo 102 0084 Phone 81 33 264 4721 m_ishihara kaku ichi co jp Kazakhstan LAMED Ltd 155 1 Tazhibayevoi Str 050060 Almaty IP Schmidt Abayavenue 3B 110 005 Kostanay Korea Kyung Jin ...