background image

EN

7

EN

IMPORTANT! 

Read the operator’s manual carefully before use and keep for future 

 reference.

Electrical safety
The pump must not be used when people are in water.

 DANGER! Electric shock! 

Risk of injury due to electric shock.

The product must be supplied through a residual current device (RCD) having  

a rated residual operating current not exceeding 30 mA.

v

 Please contact your electrician.

Mains connection lines must not be of inferior quality to the rubber hose lines  

with code number H07RN-F in accordance with DIN VDE 0620. The cable length 

must be at least 10 m.
When connecting the pump to the water supply system, the country-specific 

sanitary regulations must be observed to prevent water not of drinking water 

quality being drawn back in.

v

 If necessary, contact your sanitary expert.

The power cable of the Submersible Pressure Pump must be connected to  

a socket which is positioned at a height of 1.10 m (measured from ground).  

Take care that the power cable leads downwards.
Data indicated on the type plate must match technical data of the mains supply.

v

 Take care that the electrical connections are made within dry area, protected 

from flooding.

v

 Keep mains plug dry.

Protect plug and power cable from heat, oil and sharp edges.

  

DANGER! Electric shock!

With a cut off mains plug, moisture can get into electrical parts via the mains 

cable and cause a short circuit.

v

 Never cut the mains plug off (e. g. to feed through wall).

v

  Don’t use the power cable for plugging off.

The power cable must not be used for mounting or relocating the pump.
For submerging or lifting /securing the pump, please use the fastening rope.
Extension cables must meet the requirements of DIN VDE 0620.

In Austria
In Austria the electrical connection must satisfy the  ÖVE-EM 42, T2 (2000) / 1979 

§ 22 to § 2022.1. This requires that pumps used for swimming pools and garden 

ponds may only be powered through an isolating trans former.

v

  Please ask your electrician for his advice.

In Switzerland
In Switzerland mobile appliances which are used outdoors, must be connected 

via a residual-current device.

Visual check

v

  Before operating the pump, first make a visual check, if there is any damage  

of the pump (esp. regarding power cable and plug).

Please observe that the pump always have to be submerged at least 12 cm in 

water during operation.

  

DANGER! Electric shock!

A damaged pump must not be used.

v

  In case of damage, please have the pump checked by our GARDENA Service 

Centre.

v

  If the supply cord is damaged, it must be replaced by the manufacturer, its 

service agent or similarly qualified persons in order to avoid a hazard.

Notes on use
Sand and other abrasive substances cause increased wear and reduce the 

pump’s output.
Leaking lubricants can contaminate the pumped liquid.
DANGER! This product makes an electromagnetic field while it operates. This 

field may under some conditions interfere with active or passive medical implants. 

To decrease the risk of conditions that can possibly injure or kill, we recommend 

persons with medical implants to speak with their physician and the medical 

implant manufacturer before you operate the product.
DANGER! Small parts can be easily swallowed. There is also a risk that the poly-

bag can suffocate toddlers. Keep toddlers away when you assemble the product.

1. SAFETY

2. INITIAL OPERATION

The hose can be connected via the pump connection piece 

1

 and the 

connection nipple 

2

 [19 mm (³⁄₄") / 25 mm (1")] or via the GARDENA 

Connection System [13 mm (¹⁄₂") / 16 mm (⁵⁄₈") / 19 mm (³⁄₄")]. When using 

a 25 mm (1") hose, the pump has the maximum delivery capacity.

With a parallel connection of more than one hose or connected devices, 

the GARDENA  2­ / 4­Way  Valve  (Art.  1210 / 1194) can be used, which is 

screwed straight onto the pump connection piece 

1

.

Connect hose via connection nipple 

2

  [ Fig.  I1 ]:

25 mm (1")- and 19 mm (³⁄₄") hoses can be connected via the connec-

tion nipple.

Hose diameter

19 mm (³⁄₄")

25 mm (1")

GARDENA Hose Clamp

Art. 7191

Art. 7192

Hose connection [ Fig.  I2 ] 

Do not detach 

 nipple  [ Fig.  I3 ].

Detach nipple  

at 

<

 [ Fig.  I4 ].

25 mm (1")- and 19 mm (³⁄₄") hoses connected with a connection nipple 

2

 

must be fastened, for example with a GARDENA Hose Clamp  

Art.  7192 / 7191.

1.  Screw pump connection piece 

1

 by hand into the outlet of the pump 

until the sealing ring fits snugly.

2.  Screw connection nipple 

2

 onto the pump. (With 25 mm (1") hoses,  

first disconnect the connection nipple 

2

 at 

<

).

3.  Push hose onto the connection nipple and fix for example with  

GARDENA Hose Clamp Art. 7192 / 7191.

Connect hose via the GARDENA Connection System [ Fig. I5 ]:

19 mm (³⁄₄")- / 16 mm (⁵⁄₈") and 13 mm (¹⁄₂") hoses can be connected via 

the GARDENA Connection System.

Hose diameter

Pump connection

13 mm (¹⁄₂")

GARDENA Pump Connection Set

Art. 1750

16 mm (⁵⁄₈")

GARDENA Tap Connector
GARDENA Hose Connector

Art. 18202
Art. 18216

19 mm (³⁄₄")

GARDENA Pump Connection Set

Art. 1752

1.  Falls noch nicht montiert, das Pumpenanschluss-Stück 

1

 mit 

 geeignetem Werkzeug in den Pumpenausgang schrauben. Dabei 

 

vorsichtig anziehen, bis der Sechskant-Schraubkragen bündig  

am Pumpengehäuse anliegt.

2.  Connect hose via the relevant GARDENA Connection System.

3. OPERATION

Pump water in automatic mode [ Fig. O1 /O2 ]:

The pump must always be submerged in the fountain or water reservoir 

with the rope provided. For the pump to be primed, the pump must be 

submerged at least 12 cm. So that the filter does not become dirty, the 

pump should be fixed at least 30 cm above the ground.

1.  Attach fastening rope 

3

 to the lug 

4

.

2.  Submerge pump in the fountain or water reservoir via the fastening 

rope 

3

.

3.  Secure fastening rope 

3

.

4.  With deep fountains or shafts (from approx. 5 m), route the connection 

cable 

5

 along the fastening rope 

3

 with clips.

5.  Plug the mains plug of the connection cable 

5

 into a mains socket.  

The pump starts 3 secs. after connecting the connection cable.  

The pump is then ready for operation.

Automatic mode:
The pump pumps and switches off automatically as soon as no more 

water is drawn. Due to the check valve, the pressure is maintained in  

the hose until water is drawn via the hose. When water is drawn via the 

hose (the pressure in the hose falls below 2.6 bar), the pump switches  

on automatically.

Dry run protection (flow control):
The pump switches off automatically when there is no fluid pumped.  

The pump operates in cycles 30 secs. on – 5 secs. off (4x). This cycle is 

repeated in 1 hr, 5 hrs, 24 hrs, 24 hrs … 

The pump is operational again as soon as the pump is submerged at  

least 12 cm in the water again.

Flow control:
The flow control switches off automatically as soon as no more water is 

drawn. In the event of leakage on the pressure side (e.g. leaking pressure 

hose or tap) switches the pump on and off at short intervals. If the pump  

is switched on and off more frequently than 7 x in 2 min. (with a leakage  

Summary of Contents for 1476

Page 1: ...anurzeniowo ci nieniowa HU Haszn lati utas t s Mer l nyom szivatty CS N vod k obsluze Ponorn tlakov erpadlo SK N vod na obsluhu Ponorn tlakov erpadlo EL RU SL Navodilo za uporabo Potopna tla na rpalka...

Page 2: ...dnie z niemieck ustaw o odpowiedzialno ci za produkt niniejszym wyra nie o wiadczamy e nie ponosimy adnej odpowiedzialno ci za szkody poniesione na skutek u ytkowania naszych produkt w w przypadku gdy...

Page 3: ...3 I1 2 1 I2 2 I3 I4 I5 O1 5 4 3 O2 M1 0 9 8 7 6...

Page 4: ...ence of alcohol drugs or medicine Intended use The GARDENA Submersible Pressure Pump is intended for the private use in house and hobby gardens It is intended for draining water from fountains shafts...

Page 5: ...Keep toddlers away when you assemble the product 1 SAFETY 2 INITIAL OPERATION The hose can be connected via the pump connection piece 1 and the connection nipple 2 19 mm 25 mm 1 or via the GARDENA Con...

Page 6: ...rged at least 12 cm v Submerge pump at least 12 cm in water Problem Possible Cause Remedy The pump does not deliver any water Leakage on the pressure side Flow control switched the pump off flow 6 l h...

Page 7: ...acturer s warranty does not affect warranty entitlements against the dealer retailer If problems arise with this product please contact our Service depart ment or send the defective product along with...

Page 8: ...kteristika Pumpun ominaisk yr Pumpekarakteristikk Curva di rendimento Curva caracter stica de la bomba Caracter sticas de performance Charakterystyka pompy Szivatty jellegg rbe Charakteristika erpadla...

Page 9: ...Germany AB PO Box 7454 S 103 92 Stockholm Sverige erkl rer hermed at nedenfor anf rte enheder er i overensstemmelse med de harmoniserede EUret ningslinjer EU standarder for sikkerhed og produktspecifi...

Page 10: ...77...

Page 11: ...rdena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development K...

Reviews: