
6
5
Mounting the VTR1
5.1
Heatsinking
The approximate heat dissipation of the VTR1 can be calculated as follows:
HD = 0.25 * BR * PW * TF + 2
Where:
HD
Heat dissipation (W)
PW
Strobe pulse width (seconds)
TF
Maximum trigger frequency (Hz)
BR
Brightness of the light output (%)
Given the range of ambient temperatures and radiated sunlight, the installation must provide
enough heatsinking on the rear surface to keep the internal temperature of the VTR1 below 70
o
c.