RTxxx LED lighting controllers - User Manual
Set pulse mode
The output can be set up to pulse on a trigger input. The delay
from trigger to the start of the pulse, the length of the pulse and
the brightness are configurable.
An error is generated if the brightness setting requires a current
greater than 20A or if the combination of pulse width and setting
is not allowed.
RTc,p,d,s
RTc,p,d,s,r
Where:
c
= output channel (1 to 2, 4 or 8, depending on model)
p
= pulse width in milliseconds (0.02 to 999)
d
= delay from trigger to pulse in milliseconds (0.02 to 999)
s
= setting in percent (s = 0 to 999)
r
= retrigger delay. This parameter is optional.
Set the Option Flags
REc,m
Where:
c
= output channel (1 to 2, 4 or 8, depending on model)
m
= flags:
bit 1 =
0
1
E flag set (error detection enabled)
E flag cleared (error detection disabled)
bit 2 =
0
1
P flag set (positive triggers)
P flag cleared (negative triggers)
bit 3 =
0
1
Autosense set (controller waits for light to
be connected)
No Autosense (controller assumes light is
connected)
bit 6 =
0
1
Enable current adjust
Disable current adjust
Note:
Bit 0 is the least significant bit.
Set the Trigger Input
This command sets which input is used for pulse and switch
output modes.
—
62
—