![GARDASOFT PP610 User Manual Download Page 41](http://html1.mh-extra.com/html/gardasoft/pp610/pp610_user-manual_4324779041.webp)
PP610/612 LED lighting controllers - User Manual
Report the firmware version
VR
This command returns the current firmware version running in the
running in the PP610/PP612.
10.2
Continuous output mode
These commands set the mode of operation and define the current output
value.
Set the mode of operation
RSfSm
Where:
f
output channel (1 or 2)
m
set to
0
for continuous current.
Set the output current
RCfCcVvEe
Where:
f
output channel (1 or 2)
c
output selection. Set to
0
for non-selected
operation.
v
output current (in milliamps)
e
maximum current rating of the LED. This is
optional; if not required, omit
Ee
from the
command.
For example, to set a continuous current of 0.5A on output
channel 1:
RS1S0
Select continuous current on output 1.
RC1C0V500
Set the current on output 1 to 500mA.
10.3
Selected continuous output mode
These commands select the mode of operation and define the currents
produced by each output in selected mode.
—