This command sets the password required to access the webpages. If EY is entered on its own
then the password is cleared. There are six optional parameters, which are ASCII values for a
password from one to six letters. A value of 65 is ‘A’, 66 is ‘B’, etc to 90 is ‘Z’.
Set the Channel Flags
REc,m
Where:
c = output channel (1, 2, 3, 4)
m = Flags, where
bit 0
1 = No autosense (current rating is fixed)
0 = Autosense (current rating needs to be entered on connection)
bit 1
1 = No error detect
0 = Error detect. The PP420 continually monitors the output current and
voltage
bit 2
1 = Negative trigger. In pulse mode the trigger is the falling edge. In
switched mode a low input turns the light on.
0 = Positive trigger. In pulse mode the trigger is the leading edge. In
switched mode a high input turns the light on.
Set the trigger input
This command changes which input is used when in switched or pulsed modes.
RPc,t
Where:
c = output channel (1, 2, 3, 4)
t = trigger input (1, 2, 3, 4)
Set the output current rating
This command changes the current rating for a light.
RRc,v
Where:
c = output channel (1, 2, 3, 4)
v = rated current (10mA to 2A)
Set continuous mode
The output is set to continuous mode at a percentage of full brightness.
RSc,
s
Where:
c = output channel (1, 2, 3, 4)
s = setting in percent (s = 0 to 100)
Set switched mode
The output is set to switched mode at a percentage of full brightness.
RW
c,s
Where: