2)

Direct Mount Wood Stud Walls: Upper rail attached to a 2 inch 

(51 mm) by 8 inch (203 mm) board that is secured to the wall. 

Lower rail attached to a 2 inch (51 mm) by 4 inch (102 mm) 

board secured to the wall. Fasten each board to every available 

stud with a minimum of two fasteners.

3)

Tower Mount Struts: Provide with 2-1/2 inches (65 mm) by 2-1/2 

inches (65 mm) hollow structural steel tubular posts to support 

the guide rails.

c.

Provide a mechanical stop at the upper landing to prevent over-travel 

of the drive carriage in the event of a switch failure.

3.Provide overspeed governor and brake on upper carriage drive, containing 

mechanical overspeed sensor and lock, with electrical drive cut-out 

protection.

4.Provide with manual handwheel for emergency operation.

5.Provide platform with folding seat.

C.

Call Stations:

1.Provide wireless call stations at both landings.

2.Call stations shall be provided with directional control buttons for call and send.

3.A one-touch control system shall be used to automatically fold/unfold the platform, 

boarding ramps and passenger safety arms.

4.Provide Attendant remote control call station.

D.

Finish:

1.Design and fabricate lift to manufacturer’s standard design for indoor and outdoor 

locations.

a.

Aluminum guide rails and ramps to be anodized aluminum. Steel 

components shall be powder coated as follows:

1)

Fine Textured Satin Grey (RAL 7030).

2)

Custom color as selected by Architect from an RAL color chart.

b.

Electrical printed circuit boards and control transformers to be treated 

with a conformal coating for resistance to ambient moisture.

2.Platform Cover: Provide a durable and weather resistant nylon platform cover for 

protection.

PART 2  3EMERGENCY EVACUATION DEVICE

A.

Portable evacuation chair, Garaventa “Evacu-Trac” with steel storage enclosure:

1.Capacity:  1 person, 300 lbs (136 kg) with minimum 1.5 times safety factor.

2.Maximum Stair Angle:  40 degrees.

3.Speed Governor:  Piston brake.

4.Brake:  Manual mechanical brake, attendant must release brake bar for descent.

5.Surface Mount Cabinet: 

a.

Steel cabinet and door panel. Available only in Satin Gray, left hinged 

only.

b.

Size: Height 45-3/8 inches (1151 mm), width 20 inches (508 mm), 

depth 11 inches (279 mm).

PART 3  EXECUTION

PART 3  1EXAMINATION

 

X3 Specification  23265-A-DS   Section 14 42 13    Page 6

Summary of Contents for X3

Page 1: ...or lift attachment D Section 09260 Gypsum Board Assemblies Stair walls E Section 13650 Fire Alarm System Building Fire Alarm Integration system to connect the lift control system with the building fir...

Page 2: ...g manufacturer s full range of available colors and patterns E Verification Samples For each finished product specified two samples representing actual product color and patterns PART 1 5QUALITY ASSUR...

Page 3: ...l Free 800 663 6556 Tel 604 594 0422 Fax 604 594 9915 Email productinfo garaventalift com Web www garaventalift com B Substitutions Not permitted C Requests for substitutions will be considered in acc...

Page 4: ...straining arms for passenger emergency evacuation e Top of arms mounted 37 3 8 inches 948 mm above platform deck When in guarding position arms are located above the perimeter of the platform f Gaps b...

Page 5: ...folded position 12 Attendant Hand Held Pendant Control Provide plug in remote pendant control for attendant operation 13 Platform on Board Emergency Alarm Provide platform with an on board alarm that...

Page 6: ...arding ramps and passenger safety arms 4 Provide Attendant remote control call station D Finish 1 Design and fabricate lift to manufacturer s standard design for indoor and outdoor locations a Aluminu...

Page 7: ...ifts in accordance with in compliance with regulatory requirements specified and the manufacturer s instructions B Install system components and connect to building utilities C Accommodate equipment i...

Reviews: