en
6.1. CABINET TO CABINET
A
ü
Cabinets are of identical height and depth. Otherwise drill
through cabinet wall.
1. Insert four M6×12 bolts through both side walls at top and bot-
tom.
2. Screw on four M6 nuts from the other side.
6.2. INSERTING/MOVING STORAGE SHELF
CAUTION
Toppling shelves
Crush hazard and impact hazard for individual limbs.
» Make sure the shelf is in the correct position.
» The shelf must abut the rear of the cabinet, leaving no gap.
» The front edge of the shelf must not project beyond the shelf car-
rier.
C
1. Insert four shelf carriers per shelf at identical height in socket
strip.
» Shelf carrier’s hooks face downwards.
2. Set the shelf down on shelf carriers.
» The shelf must abut the rear of the cabinet leaving no gap, it
must sit firmly on the shelf carrier. The front edge of the shelf
must not project beyond the shelf carrier.
7. Commissioning
7.1. LAPTOP CABINET
1. Insert the mains plug into a mains socket.
7.2. BATTERY CHARGING CABINET
1. Plug 5-pin 400-V/16-A connector into three-phase outlet socket.
2. Switch on main switch.
8. Maintenance
Interval
Action
Performed by
Once a week in
rooms with nor-
mal levels of air
pollution
1. Remove cover panel with a
standard screwdriver.
2. Clean filter.
3. Put cover panel back in
place.
» Cover panel engages.
Trained spe-
cialist for elec-
tro-technical
work
Once a day in
rooms with heavily
polluted air
Before the start of
each shift
Check for external signs of
damage, for defects and for
good condition. Check the
edges and guides for signs of
wear.
4. If defective, immediately
block access and prevent
use.
5. Have the damage repaired
immediately.
Trained person
Occasionally
Grease any locks and wheels
with multi-function oil.
Trained special-
ist for mechan-
ical work
Tab. 1:
Maintenance activities
9. Rectification of faults and malfunctions
Fault
Possible
cause
Action
Performed by
Socket
strips are
un-
powered.
Mains plug
not plugged
in.
Fuse tripped.
No power
supply.
Unplug mains plug and
plug in again.
Reset fuses.
Switch on main switch.
Switch on on/off switch on
socket.
Trained spe-
cialist for elec-
tro-technical
work.
10. Technical data
10.1. G DIMENSIONS
25 mm are equivalent to 1 G.
10.2. LAPTOP CABINET
Weight
46 kg
Electrical installation
Sockets
7x, type F
Plug socket rated voltage
16 A
USB ports
7x, USB 2.0 type A
USB output voltage
5 V DC (± 5%)
USB charge current
1 A
10.3. BATTERY CHARGING CABINET
Size
1000/DE
1250/DE
2000/DE
Weight
88 kg
95 kg
120 kg
Load capacity of
shelf
100 kg
100 kg
100 kg
Load capacity of
drawers
-
-
75 kg
Total load capa-
city
1000 kg
1000 kg
1000 kg
Electrical installation
i
For details on internal electrical installation, refer to included test re-
port.
Sockets
4 socket strips with 6 sockets
each, 230 V, type F
Plug socket rated voltage
16 A
IP Index of Protection
IP 20
Cabinet shell fan
Stage
1~
Rated AC voltage
230 V
Frequency
50/60 Hz
Speed
2700 rpm
Power consumption
11 W
Noise pressure level
34 dB(A)
Ambient temperature
-10°C to +70°C
11. Disposal
Comply with the national and regional environmental protection
and disposal regulations for correct disposal or recycling. Segregate
items into metals, non-metals, composite materials and consum-
ables and dispose of them responsibly.
11