1/3
LIMIT SWITCH SETUP
(Just for motors with electronic limit switch)
ATTENTION: ALWAYS SET THE UP LIMIT FIRST
1
Push the PROG-FC button until the
motor makes a brief jog.
Note: during “programming mode”
the operations are in “deadman
control”
2
Press and hold the UP button and
run the motor to the desired UP limit
position.
3
Press STOP to set the UP limit position.
The motor makes a brief jog.
4
Press and hold the DOWN button and
run the motor to the desired DOWN limit
position.
5
Press STOP to set the DOWN limit
position. The motor makes a brief jog.
Note: accurate limit setting can be performed when UPWARD or
DOWNWARD by pressing the PROG-FC button a second time. The motor
then moves slowly in steps towards the desired limit. Always press STOP
button to set the limit position.
LIMIT SWITCH