NVC/IPE Series Installation Guide
IPE5510 Installation Guide
01A.02
12
Caution
!
Do not connect the speaker without amplifier.
②
Sensor (DI) connection
The camera provides 1 channel D/I. It can be connected to either a voltage type sensor or a
relay type sensor as the following figures. It can be selected by software.
Input voltage range: 0VDC minimum to 5VDC maximum, Max 50mA
Input voltage threshold: 4.5V
Caution
!
Do not exceed the maximum input voltage or relay rate.
③
Alarm (DO) connection
The camera provides 1 channel D/O.
Relay Rating: Max 24VAC 500mA or 12VDC 1A
Caution
!
Do not exceed the maximum relay rating.
+5V
DI
COM
DI
COM
+
-
Relay Type
Voltage Type
+
-
Output of
Sensor
Output of
Sensor
Internal
Internal
+
-
Summary of Contents for ZN-PTZ12VP-XT