background image

WIDE DYNAMIC RANGE 

ZC-DWT4312 NHA/ZC-DWT4312 PHA

Operation Manual 

Camera Adjustments 

 

Camera Adjustment and Programming 

With the exception of the focus and field of view adjustments (made using levers A and B), all 

settings for the ZC-DWT4312 camera are made using its onscreen menu display. A functioning 

video  monitor  and  a  separate  plug-in  service  board  (C)  are  required  to  view  and  select 

options.

Menu Description 

PRESETS 

These are "factory-set" general configurations. Select from the preconfigured camera modes 

for  the  best  performance  in  the  specified  environment.  Pressing  the  ENTER  key  on  the 

selected option will display the pre-configured set-up parameters. 

NORMAL - This should provide the most versatile settings for general purpose applications. 

INDOOR or OUTDOOR - These settings are optimized for indoor/outdoor lighting conditions. 

FLUOR1 - Line lock recommended. 

INT 1 - Internally generated sync. 

LL - Line lock - sync is locked to the AC supply cycle and permits adjustment of V-phase to 

correct  vertical  sync  picture  roll.  (Applicable for  24  V  AC  supply  only.  If a  12  V  DC  power 

supply is used, then the camera will run in INT1 or INT2.) 

INT 2 - Internal flickerless - Internally generated sync that can reduce flicker under florescent 

lighting. 

FLUOR2 - DC IRIS recommended. 

EXPOSURE 

EXPOSE  MODE  has  4  Exposure  modes  for  selection.  Each  Exposure  mode  uses  the 

electronic shutter differently and is suitable for a specific environment. 

AGC - Automatic gain control - When low light priority is set to gain, gain increases as light 

decreases up to the maximum set using gain limit. No color artifacts are visible nor does the 

dynamic range decrease as gain increases. 

WDR RANGE CTRL - Use WDR control, electronic shutter control, mechanical iris control, 

and the low brightness zone controls selected in LOW Lux MODE to automatically control the 

exposure  time.    Seamless  switching  between  control  zones  delivers  shockless  AE.   

**Requires a separate mechanical lens. 

AE PREFs - Automatically optimizes the scene for highlights or for shadows. 

SHUTTER LIMIT - Limits the shutter value. 

WHITE BALANCE 

WHITE  BALANCE  has  4  modes  for  selection.  Each  mode  uses  the  electronic  shutter 

differently and is suitable for a specific environment. 

ATW Xtnd - Extended auto white balance range - use this setting for scenes that may have an 

extremely wide range of color temperatures. 

ATW Normal - Selects a normal auto white balance range for general operation. If necessary, 

the range is configurable with low limit (to help with reds) and high limit (to help with blues) 

adjustments. 

AWB - Save or cancel AWB and all changes. 

MANUAL - Allows manual setting of the image's color temperature. This can be achieved by 

using the Kelvin option, by the method familiar to the installer. This setting is also good for 

static environment applications where the lighting conditions never change, such as in indoor 

hallways. 

VIEWING 

MIRROR - This mode reverses the top and bottom sides of the linear. 

GAMMA  MODE  -  Select  appropriate  gamma  mode  for  type  of  display.  Gamma  correction 

compensates  for  a  non  linear  grayscale  in  a  display  device  or  to  create  non-standard 

luminance. 

MANUAL  -  Manual  Gamma  may  be  used  to  enhance detail in low  light  areas  of  an image 

which would normally not be visible with highlights present in the image. 

SHARPNESS - Adjusts overall image sharpness. 

SATURATION - Adjusts overall color content of the image. 

SETUP 

IRIS- DC GAIN - Adjusts the iris control gain when using a DC iris. 

AI THRESH - Adjusts the threshold at which the automatic iris becomes active. 

DAY/NIGHT  SETUP  -  Day/Night  operation.  This  feature  may  be  used  to  improve  low  light 

performance  by  reducing  noise  from  the  video  signal  or  force  the  camera  into  night  mode 

regardless of lighting conditions. 

SAVE/RESTORE 

RESTORE  USER  SETTINGS  -  This  will  undo  any  changes  made  since  the  last  time  the 

settings were saved. 

SAVE USER SETTINGS - Save any programming changes to ensure they are retained after 

power loss or reset. If changes are not saved, the camera will revert to the previous settings 

on power-up. 

RESTORE FACTORY SETTINGS - Restore camera settings to factory default - full reset, all 

previous programming will be lost including the video standard, which will default to NTSC. 

RESET CAMERA - This is a soft reset and has the same effect as cycling the camera power. 

SYSTEM INFO - Displays the camera firmware version. 

ZC-DWT4312NHA/PHA Specifications 

r

o

s

n

e

S

m

i

x

i

P

t

n

e

m

e

l

E

e

r

u

t

c

i

P

e

g

a

m

I

)

H

(

0

2

7

t

n

e

m

e

l

E

e

r

u

t

c

i

P

e

v

it

c

e

ff

)

V

(

0

4

5

E

0

2

5

)

s

e

n

il

V

T

(

n

o

it

u

l

o

s

e

R

n

o

it

a

n

i

m

u

ll

I

m

u

m

i

n

i

M

B

d

2

4

>

o

it

a

R

N

/

S

ti

b

7

1

/

B

d

0

2

1

e

g

n

a

R

c

i

m

a

n

y

D

e

d

i

W
Wide Dynamic Range Area 

1 Zone - Fully Adjustable 

x

2

3

x

a

m

,

x

2

tl

u

a

f

e

D

r

e

tt

u

h

S

w

o

l

S

0

0

0

0

0

1

/

1

~

0

6

/

1

r

o

0

5

/

1

r

e

tt

u

h

S

c

i

n

o

rt

c

e

l

E

ff

O

/

n

O

/

o

t

u

A

N

D

S

t

h

g

i

N

/

y

a

D

h

c

u

o

T

-

1

,

B

W

M

,

W

T

A

e

c

n

a

l

a

B

e

ti

h

W
Auto White Balance Range 

2200°K ~ 7500°K, 2000°K ~ 11000°K 

k

c

o

L

e

n

i

L

/l

a

n

r

e

t

n

I

m

e

t

s

y

S

c

n

y

S

C

S

T

N

r

o

f

z

H

4

.

2

6

-

z

H

7

5

L

A

P

r

o

f

z

H

2

5

-

z

H

5

.

7

4

d

e

c

n

a

l

a

b

n

U

m

h

o

5

7

,

p

p

V

0

.

1

t

u

p

t

u

O

o

e

d

i

V
Power Range 

AC: 24 V AC   20% or DC: 12 V DC -10% +20% 

n

o

it

p

m

u

s

n

o

C

r

e

w

o

P

C

°

0

5

+

o

t

C

°

0

1

-

e

r

u

t

a

r

e

p

m

e

T

g

n

it

a

r

e

p

O

C

°

0

6

+

o

t

C

°

5

3

-

e

r

u

t

a

r

e

p

m

e

T

e

g

a

r

o

t

S

(

0

4

1

n

o

i

s

n

e

m

i

D

l

a

n

r

e

t

x

E

φ

)mm x 100(H)mm 

g

0

0

6

t

h

g

i

e

W

Lens Specifications 

ZC-DWT4312NHA/PHA Menu Map 

Press the ENTER button on the control panel for three seconds to view the menu. 

h

t

g

n

e

L

l

a

c

o

F

.

o

N

-

F

e

g

n

a

R

s

ir

I

m

5

.

0

e

c

n

a

t

s

i

D

t

c

e

j

b

O

m

u

m

i

n

i

M
Angle Of View 

Diagonal 

125.7°~29.9° 

l

a

t

n

o

z

ir

o

H

l

a

c

it

r

e

V

e

p

y

T

s

n

e

L

3.3~12 mm

F1.4

F1.4~F360

89.8°~23.9°
63.6°~17.9°

Aspherical

4.2W

1.7 lx @ F1.4

Reviews: