EG-9
Attaching the service monitor
Use the service monitor cable to check and adjust camera direction, focus, and
angle on a service monitor.
The service monitor is not supplied
in the cell. Please have one ready.
Adjusting the camera direction
The camera body is set in a tri-axial mounting allowing movement in the pan, tilt,
and rotational planes.
1
Adjust the direction of the lens so it faces the subject.
350° Pan
350° Rotation
180° Tilt
Indicates the top of
the camera.
Using the camera in a near-horizontal position will show the camera cover on screen.
Forcibly adjusting the camera to point in directions beyond the limits of the mounting
may cause the cable to catch on internal components and damage the camera.
2
When you have finished adjusting the direction of the lens, tighten the locking screw
with a screwdriver.
Locking screw
Adjusting the view angle, focus and iris
Move the lever to adjust focus and angle of view.
Focus/View angle
adjustment lever