ZA-NVE12K Hardware Manual 

2010/2-1 E 

 3 

Safety and Regulatory Information 

WARNING

: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE 

TO RAIN OR MOISTURE. THE APPARATUS MUST NOT BE EXPOSED TO DRIPPING OR 
SPLASHING AND NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHOULD BE 
PLACED ON THE APPARATUS. 

 
CAUTION:

 TO PREVENT ELECTRICAL SHOCK, IF THE UNIT IS PROVIDED WITH A 

POLARIZED PLUG, DO NOT CONNECT THE PLUG INTO AN EXTENSION CORD, 
RECEPTACLE, OR OTHER OUTLET UNLESS THE PLUG CAN BE FULLY INSERTED WITH 
NO PART OF THE BLADES EXPOSED. 
 

CAUTION:

 TO ENSURE REGULATORY AND SAFETY COMPLIANCE, USE ONLY THE 

PROVIDED POWER AND INTERFACE CABLES.   
 

CAUTION:

 DO NOT OPEN THE UNIT. DO NOT PERFORM ANY SERVICING OTHER THAN 

THAT CONTAINED IN THE INSTALLATION AND TROUBLESHOOTING INSTRUCTIONS. 
REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL. 
 

CAUTION:

 FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY 

WITH SAME TYPE AND RATING OF FUSE. 
 

CAUTION:

 RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. 

DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.   
 

RACK MOUNT INSTRUCTIONS 

 
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating 
ambient temperature of the rack environment may be greater than room ambient. Therefore, 
consideration should be given to installing the equipment in an environment compatible with the 
maximum ambient temperature (Tma) specified by the manufacturer.   
 
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air 
flow required for safe operation of the equipment is not compromised.   
 
C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous 
condition is not achieved due to uneven mechanical loading.   
 
D) Circuit Overloading - Consideration should be given to the connection of the equipment to the 
supply circuit and the effect that overloading of the circuits might have on overcurrent protection and 
supply wiring. Appropriate consideration of equipment nameplate ratings should be used when 
addressing this concern.   
 
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular 
attention should be given to supply connections other than direct connections to the branch circuit (e.g. 
use of power strips)." 
 

FCC COMPLIANCE   

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation. 
 

Summary of Contents for ZA-NVE12K series

Page 1: ......

Page 2: ... 3 4 Ejecting and inserting blades 13 Ejecting a blade 13 Inserting a blade 13 3 5 Factory Default Settings 13 3 6 Rebooting 14 4 Power Supplier Unit 15 4 1 Specifications 15 4 2 Unit view 15 4 3 Electrical characteristics 16 4 4 Environmental characteristics 17 4 5 Mechanical characteristics 17 5 Fan Unit 19 5 1 Description 19 5 2 Unit view 19 5 3 Electrical characteristics 19 5 4 Environmental c...

Page 3: ...ient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not comp...

Page 4: ...VE12K Hardware Manual 2010 2 1 E 4 CE COMPLIANCE This is A class product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures ...

Page 5: ...nit operation Self diagnosing Applied device ZN RS4000AE series It is the blade version of ZN S4000AE series ZN RS4000AE Main features High Quality Compression in real time streaming GANZ encoder provides high quality MPEG 4 and MJPEG encoding at D1 in real time Network RTP RTSP and unicast multicast are supported Streaming support dual streaming mode such as different codec resolution bit rate an...

Page 6: ...e Single Power Supply Power Consumption 2600mA at 12V Typically 48W Video Input 4 ch BNC Type Audio Input 4 ch 2 5 mm Pitch Terminal Block Pluggable Audio Output 1 ch 2 5 mm Pitch Terminal Block Pluggable Digital Input Output 4 2 ch 2 5 mm Pitch Terminal Block Pluggable RS 232C RS 485 1 1 ea Connector Each slot Network 10 100 Base T Fan Unit 6 500rpm x 2ea Temperature 0 60 32 140 Humidity Up to 85...

Page 7: ...ZA NVE12K Hardware Manual 2010 2 1 E 7 2 2 Unit view Figure 1 GANZ encoder subrack ...

Page 8: ...re 2 Rear top and front view of subrack Figure 3 Detailed rear view of subrack video audio digital input output etc Rx Tx RS 232 2 C 1 2 3 3 4 1 2 4 1 C Aout DI DO Ain 1 IO RS 485 Reserved Ethernet 3 USB 3 IO3 Vin3 1 Vin3 2 Vin3 3 Vin3 4 RS 232 ...

Page 9: ...ZA NVE12K Hardware Manual 2010 2 1 E 9 Figure 4 Detailed rear view of subrack power cord Figure 5 Detailed rear view of subrack RACK ID Figure 6 Leftside and Rightside view of subrack ON 1 2 3 4 0 I ...

Page 10: ...ZA NVE12K Hardware Manual 2010 2 1 E 10 2 3 Mechanical characteristics Mechanical characteristics of subrack z Dimension Width inch 19 Height U 1 U Depth mm 286 1mm ...

Page 11: ... Audio Opti onal Data Format PCM software compression G 711 uLaw Network 10 100 Base T De interlacing Supported by hardware Motion Detection Supported by hardware OSD Supported by hardware Video Stream Encryption AES Protocols SNTP DHCP UDP TCP RTP RTSP unicast multicast Parameters Min Typical Max Units Peak to peak amplitude 0 5 1 1 35 V Sync amplitude 143 286 386 mV Horizontal lock range 6 2 of ...

Page 12: ...ZA NVE12K Hardware Manual 2010 2 1 E 12 3 2 Unit view Figure 7 GANZ encoder blade Figure 8 Front top side view of a blade ...

Page 13: ...e 1 Unscrew two screws 2 Remove the blade from the rack as figure 9 Figure 9 Ejecting a blade Inserting a blade 1 Insert the blade 2 Screw to the rock direction 3 5 Factory Default Settings Factory default settings are as follows IP address 192 168 xx yy refer to 2 3 Serial Number MAC Address Mask 255 255 0 0 Gateway 192 168 0 1 User ID root Password pass Lock Unlock Lock Unlock Lock Unlock Lock U...

Page 14: ...tus LED starts blinking rapidly 3 Release Reset button when Status LED blinks slowly 3 6 Rebooting Reset can be carried out as follows 1 Press Reset for 1 second When Reset function is activated Status LED and Network LED will blink together twice User may stop pressing Reset at this point 2 When Reset function has been completed LEDs will stop blinking Convert the Hexadecimal number to Decimal nu...

Page 15: ...ZA NVE12K Hardware Manual 2010 2 1 E 15 4 Power Supplier Unit 4 1 Specifications z DC Power Supplier Unit PSU z 19 1U Rack Mountable 10HP DC12V 74 4W 4 2 Unit view Figure 10 Power supplier unit ...

Page 16: ...30VAC INRUSH CURRENT Typ COLD START 18A 115VAC 36A 230VAC Input LEAKAGE CURRENT 1mA 240VAC 115 150 rated output power OVER LOAD Protection type Hiccup mode recovers automatically after fault condition is removed 13 8 16 2V PROTECTION OVER VOLTAGE Protection type Hiccup mode recovers automatically after fault condition is removed FUNCTION REMOTE ON OFF RC RC 0 0 8V power on 4 10V power of SAFETY ST...

Page 17: ...uipment The final equipment must be re confirmed that it still meets EMC directives 4 4 Environmental characteristics WORKING TEMP 20 70 Refer to output load derating curve WORKING HUMIDITY 20 90 RH non condensing STORAGE TEMP HUMIDITY 20 85C 10 95 RH TEMP COEFFICIENT 0 04 C 0 50C Environmental characteristics VIBRATION 10 500Hz 2G 10min 1cycle Period for 60min each along X Y Z axes Table 4 Enviro...

Page 18: ...ZA NVE12K Hardware Manual 2010 2 1 E 18 Figure 11 Front and top view of PSU ...

Page 19: ...ns EA 2 5 2 Unit view Figure 12 Fan unit 5 3 Electrical characteristics Parameter Units Value Rated Voltage DC 12 Input Voltage Operating Voltage V DC 10 2 13 8 Input Power W 1 2 Maximum Air Flow m3 min 0 17 x 2EA 0 34 At Average Value in Free Air Fan Speed min 1 6500 Table 6 Electrical specification of Fan unit ...

Page 20: ...ange Storage 40 C 70 C Table 7 Environmental specification of Fan unit 5 5 Mechanical characteristics Casing Impeller Plastic Black 94V 0 Lead Wire UL1061 AWG26 Red Black Dimension 1 575 in sq x 394 in 40mm sq X 10mm Mechanical characteristics Low Weight 0 525oz 15g Table 8 Mechanical specification of Fan unit Figure 13 Top view of fan unit ...

Reviews: