Area Threshold:
Defines the percentage area of the image which must be changed for tamper-
ing to be triggered.
•
Suppress Alarm on light:
In scenarios where sudden changes in lighting such as switching
on/off indoor lighting can cause false tamper events.
– On:
Enables the suppressing feature.
– Off
Disables the suppressing feature.
Note: The option will reduce sensitivity to genuine alarms and should be used with caution. Remember to
Apply
changes for them to take effect
11.2 Event Action
•
Enable TCP Event:
Defines if a TCP notification will be sent when the tamper detection triggers.
– On:
Enables the TCP event feature.
– Off
Disables the TCP event feature.
•
Enable HTTP Event:
Defines if a HTTP notification will be sent when the tamper detection trig-
gers.
– On:
Enables the HTTP event feature.
– Off
Disables the HTTP event feature.
•
Action Rule:
Allows actions, defined in the camera, to be triggered when an event occurs.
11.3 Apply
Click
Apply
to save the current settings.
50
Ganz GXi Series
VCA Interface Manual v1.0.66
07.12.22