background image

 

15

 

 

 

 

 

 

 

 

                    INSTALLATION

 

 

Communication Port 

   
 

                 

 
 

 
 
 
 

 

 

RS-485 Connection

 

Connect a  PTZ  Camera  of  Keyboard Controller. 
After connecting the control device, be sure to match the connection settings between DVR and  the
device. Refer  to  communication settings in 

“Operation  Manaul”

.

 

Connect  three signals  (

[D+],[D-],[GND]

)  between  DVR  and of the control  device  by   

using  provided  terminal  block. 

 

 

For RS-485 connection, refer to the user

’s manual of the control  devices. 

 
                                                There  is  two  ports  of  RS485  on  rear  panel. 
                                                    RS-485_1    :  Connect  Keyboard  controller 
                                                    RS-485_2    :  Connect  PTZ  cameras 
 
 
 
 

RS-232C Connection

 

You  can  connect  PTZ  cameras,  POS  or  ATM  devices. 
For  connection  of  the  text-in  device,  refer  to  the  user  manual  of  the  text-in  device. 
 

 

Signal  connection  for  POS  and  ATM  is  scheduled  to  be  upgraded  later. 

 

Audio Device Connection 

You can connect an audio output device such as speaker amplifier. 
Connect the audio input device such as microphone to the rear Audio In port, connect the audio 
output device such as speaker amplifier to the Audio Out port. 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DIGIMASTER DR-16FX5-3TB

Page 1: ...1 ...

Page 2: ...2 CONTENT OVERVIEW 3 Before Installation 4 Key Features 6 Front Panel 7 Rear Panel 8 Remote Control At a Glance INSTALLATION 10 HDD Installation 12 Basic Layout 13 Connecting to an external devices ...

Page 3: ...it with wet hand Do not insert a conductor in the vent of the ventilation system Do not apply excessive force to unplug the power cord Disassembly Cleaning When cleaning on the surface use a dry cloth Do not wipe the product using water paint thinner or organic solvents Do never dismantle repair or modify the product by your own During installation To prevent an accident or physical injury and to ...

Page 4: ...g cell phones 16 channels of 960H camera videos can be displayed at 480 NTSC 400 PAL fps in real time Up to 16 channels of 960H camera videos can be saved at maximum 480 400 fps Simultaneously recording and playback of maximum 16 channels Supports H 264 HP CODEC Auto alarm feature with self diagnostics on the system HDD S M A R T network error etc Supports dual streaming for remote access service ...

Page 5: ...5 OVERVIEW What s included Mouse Remote Control Power Cable Batteries AAA x2 Screws Terminal Blocks User manual CD Quick Guide ...

Page 6: ...l from the remote control USB Used for connecting USB storage or mouse Status LED Show the status of power recording or network connection together with the corresponding alarm HDD 1 5 eSATA HDD1 HDD2 HDD3 HDD4 HDD5 eSATA Indicates connection status of internal external storage devices ...

Page 7: ... or an output type 9 VGA VGA monitor video output port 10 AUX Additional SPOT output Connect to a TV monitor 11 HD MONITOR HD monitor video output port 12 eSATA Connection port for external eSATA storage 13 USB Used for connection USB Storage or mouse 14 WAN UPLINK LAN DOWN LINK Network port for connection to the Internet router or hub Reserved DO NOT connect 15 ALARM IN ALARM OUT RELAY RS 485 RS ...

Page 8: ...remote control ID DISPLAY Switch the split mode SEQ Switch to sequence mode SNAPSHOT Turn on or off the power Used to change the direction or adjust the play speed in playback mode EXIT Exit from the current screen and return to the previous screen ENTER Select a menu item or apply your settings LOG Display the log list KEYLOCK Lock any operation on the unit AUDIO Display the audio channel selecti...

Page 9: ... Setup menu set the REMOTE CONTROLLER ID and press Apply Select between 00 and 99 For more details refer to SYSTEM SETUP The remote control will be active only if the remote control ID matches with that of the DVR s system ID 2 Press the ID button on the remote control The default remote control ID is 00 3 Use the number buttons to provide a two digit ID If you want to enter 01 for instance enter ...

Page 10: ...ews on both ends of DVR 2 Pull the front side of the unit forward to separate it 3 Hold the middle of the HDD brackets handle with index finger and pull it toward while sustaining the bracket handle with your thumb and middle finger as shown in the illustration ...

Page 11: ...ck to both ends of the bracket to fix When installing HDD make sure to Install in the correct direction 6 Push the bracket installed with new HDD back into the main units it is completely inserted 7 Assemble the front panel back to the unit When assembling the front panel to the main unit make sure the marked part is tightly attached 8 Fasten 2 screws on both ends of main unit ...

Page 12: ...depending on the distance between the camera and DVR it s recommended to consult an authorized installer when installing the DVR Camera Full HD Monitor Speaker MIC Sensor Alarm Control Device ATM SPOT Monitor IP Router or HUB Full HD Monitor eSATA Storage SPOT Monitor POS Access Controller Mouse ...

Page 13: ...s both 50Hz and 60 Hz inputs For NTSC setting it works at 60Hz Make sure to connect the product to a monitor that supports 1920x1080 1270x1024 or 1280x720 Power Connection Connect the power cable supplied with the product into the power socket on the main unit s rear side Make connection when the power is not applied yet Arrange up the cables and be careful not to peel off the cable coating Do not...

Page 14: ...ovided terminal bloack 2 Insert the alarm signal wire into the hole of the NO or NC input prot shown below the screw and tighten the screw Check the relay type befere selecting a proper NO Normal Open normally Open but switching to Close if an alarm out occurs COM Insert the grounding wire NC Normal Close Normally Close but switching to Open if an alarm out occurs 3 Insert the ground signal wire i...

Page 15: ...anual of the control devices There is two ports of RS485 on rear panel RS 485_1 Connect Keyboard controller RS 485_2 Connect PTZ cameras RS 232C Connection You can connect PTZ cameras POS or ATM devices For connection of the text in device refer to the user manual of the text in device Signal connection for POS and ATM is scheduled to be upgraded later Audio Device Connection You can connect an au...

Page 16: ...port USB Device You connect and use USB storage devices for backup of recorded video saving snapshot firmware updating importing exporting user configurations Also USB mouse can be connected for DVR manipulations If you need to connect a USB HDD with a high power consumption it is recommended to use a separate power source for that HDD External HDD For backup only USB Storage Mouse USB HDD for bac...

Page 17: ... local PC in the format of http IP address web service port Ex http 192 168 1 23 8080 The web service port is set to 8080 by default From the Network Setup screen you can change the port number 4 Provide the ID and password before logging in Then you can view the monitoring screen Access ID factory default ADMIN P W 1234 For the security purpose change the password before you use the product for t...

Page 18: ...nd enter the DDNS address in the address bar web browser of the remote PC or of the dedicated software program or mobile phone For the IP and DDNS address settings refer Operation manual 4 If the MAC address of the DVR is 00 1C B8 12 34 56 and the web port number is 8080 enter http 001CB8123456 dvrlink net 8080 in the address bar of the web browser If you have renamed DDNS as mydvr you can make ne...

Reviews: