This symbol indicates that there is a possibility of injury or damage to 

equipment.

(1)  Use only 24V AC power supply marked class 2 or +12V DC regulated power 

supply marked class 2. 

(2) To 

prevent 

fi

 re or electrical shock, UL listed class 2 wiring should be used for the 

12V DC or 24V AC input terminal.

(3)  Be sure to connect each lead to the appropriate terminal. Wrong connection may 

cause malfunction and / or damage to the video camera.

(4)  Do not attempt to aim the camera at the sun or other extremely bright objects that 

cause smear to appear irrespective of whether the camera is operating or not. This 
can damage the CCD (Charge Coupled Device).

(5)  Do not place the camera in the following locations.

1

   Locations subject to extremely high or low temperatures.

(Operating temperature range: -10°C to +50°C {14°F to 122°F})

(Storage temperature range: -20°C to +60°C {-4°F to 140°F})

2

   Locations where there are large amounts of water vapor and steam.

(6)  Ensure the location selected is suf

fi

 ciently strong enough to support the weight of 

the camera and is free from vibration.

(7)  When this camera is installed near equipment that emits a strong electromagnetic 

fi

 eld, some irregularity such as noise on the monitor screen may happen.

(8)  Be sure  to use screws suitable for the type of material to which the camera is 

being mounted.

(9)  Do not allow the camera to be subjected to strong impacts or shocks. The camera 

could be damaged by improper handling or storage.

(10)  Never attempt to disassemble or modify the camera.
(11)  If an abnormality should occur, immediately turn off the power and consult your 

dealer.

This device complies with Part 15 of the FCC Rules. Operation is subject to following 

two conditions:
(1)  This device may not cause harmful interference. 
(2)  This device must accept any interference received, including interference that may 

cause undesired operation.

Thank you for your purchase of this product. Before operating the product, 

please read this instruction manual carefully to ensure proper use of the 

product. Please store this instruction manual in a safe place for future 

reference.

CONTENTS

PRODUCT FEATURES ............................................................................ EG-2
SAFETY PRECAUTIONS ......................................................................... EG-2
PARTS DESCRIPTION ............................................................................ EG-3
INSTALLATION AND ADJUSTMENT ...................................................... EG-4
SPECIFICATIONS .................................................................................... EG-7

PRODUCT FEATURES

 

High resolution 540TVL and low light performance surveillance camera with a built-in 

1/3” CCD.

 

A stylish all weather outdoor housing ideal for installations requiring a discreet 

appearance and outdoor performance.

 

Integrated Computar varifocal lens allows for versatile applications and easy 

installation.

 

Outstanding 0 lux performance with built in IR LEDs.

 

Digital Day/Night feature switches to B/W image at night.

 

Photocell activates IR light at night.

 

Easy cable management with cable feed-through bracket.

 

Built-in 20 LED lights.

 

IP66 rating for all weather conditions.

 

24V AC / 12V DC Auto Sensing Dual Voltage.

SAFETY PRECAUTIONS

The installation should be made by a quali

fi

 ed service person and should conform to all 

local codes.

This symbol indicates that there is a possibility of death or damage to operator 

or others.

To prevent 

fi

 re or electric shock, do not expose this product to rain or moisture.

(US)BCH-IR.indd   Sec1:2

(US)BCH-IR.indd   Sec1:2

2009/04/08   11:54:20

2009/04/08   11:54:20

Summary of Contents for BCH-IR312NA

Page 1: ......

Page 2: ...ing or storage 10 Never attempt to disassemble or modify the camera 11 If an abnormality should occur immediately turn off the power and consult your dealer This device complies with Part 15 of the FC...

Page 3: ...cover 4 Sunshield 5 Focus adjustment lever Lock screw 6 View angle adjustment lever Lock screw 7 DIP SW AGC ON OFF FL ON OFF BLC ON OFF ALC ELC 8 DC iris level adjustment volume 9 Service jack socket...

Page 4: ...ceiling or wall Use the template included to mark out the position on the ceiling or wall where you want to install the unit When running cables through the interior of the ceiling or wall use the te...

Page 5: ...hat the field conditions are suitable before installing the camera unit Connecting the cables Connect the power and video cables Connect the video cable from the monitor and the coaxial video cable at...

Page 6: ...emporary video connection when focusing the camera Adjusting the DIP Switch Mode Each of the following functions can be adjusted by ON OFF of the Switch 1 ELC ALC ELC Easy back focus adjustment to max...

Page 7: ...ystem Internal only Electronic shutter 1 60 sec FL OFF 1 100sec FL ON White balance ATW Power supply AC 24V 10 60 1Hz DC 12V 10 Power consumption DC 12V 6W AC 24V 5 5W Ambient temperature Operation 10...

Page 8: ...Focal length 3 3mm 12mm Iris DC auto iris F1 4 F360C Angle of view Wide to Tele D 125 70 29 90 H 89 80 23 90 V 63 60 17 90 The specifications and or appearance of the product may change without a prio...