background image

4

www.gantner.com

Electrical connections

TCP/IP with external power supply

GAT Info 6100

3

1

2

R

X +

TX

 -

TX

 +

GND

N

O 1

C 1

IN1 -

IN1 +

R

X -

VI

N +

TCP/IP

Power supply unit

V

Out+

GND

A

B

Mains power

  Safety instructions

-  This device must be installed by qualified personnel only.
-  The applicable safety and accident prevention regulations 

must be observed.

-  Safety devices must not be removed.
-  Please observe the technical data of the device specified 

on the data sheet.

-  The device must be disconnected from the power supply 

prior to installation, assembling or dismantling.

Valid from July 1

st

, 2016 • Technical data subject to modification without notice! 

DB_GAT-INFO6100--EN_12.indd • Part No.: 860380

Power supply

DC power (see technical data) supplied by a separate power supply unit 
(LPS and SELV - Limited Power Source and Safety Extra Low Voltage) (1). 
The power input is protected against reverse polarity.

Connection to the device front part

The socket (3) for the connection cable between the device front and rear 
parts must be clean to ensure correct operation.

Relay output

No function.

Optocoupler input

No function.

568A

568B

TX +

green/white

orange/white

TX -

green

orange

RX +

orange/white

green/white

RX -

orange

green

Applicable for the following devices:
- GAT Info 6100 F

FCC NOTICE (Class B)

This device complies with part 15 of the FCC Rules. Operation is subject to the 
following two conditions: (1) This device may not cause harmful interference, and 
(2) this device must accept any interference received, included interference that 
may cause undesired operation.

Note:

 This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there 
is no guarantee that interference will not occur in a particular installation. If this equipment 
does cause harmful interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the interference by 
one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that of which the receiver
   is connected.
- Consult the dealer or an experienced radio/TV technician for help.

FCC Warning Statement

[Any] changes or modifications not expressly approved by the party responsible for compliance 
could void the user‘s authority to operate the equipment.

GANTNER is committed to meeting or exceeding the requirements of the 
RoHS directive (2011/65/EU). The RoHS directive requires that manufacturers 
eliminate or minimize the use of lead, mercury, hexavalent chro-mium, cadmium, 
polybrominated biphenyls and polybrominated diphenyl ethers in electrical and 
electronic equipment sold in the EU after July 1, 2006.

This product is herewith confirmed to comply with the requirements set out 
in the Council Directives on the Approximation of the laws of the Member 
Statesrelating to Electromagnetic Compatibility Directive 2004/108/EG.
This product is in conformity with the following EC directives, including all 
applicable amendments:
- 1999/5/EC (R&TTE directive)
- 2004/40/EC (Limitation of human exposure to electromagnetic fields)
- 2011/65/EU (Restriction of the use of certain hazardous substances in
  electrical and electronic equipment)

 

The WEEE symbol on GANTNER products and their packaging indicates that the 
corresponding material must not be disposed of with normal household waste. Instead, 
such marked waste equipment must be disposed of by a designated electronic waste 
recycling facility. Separating and recycling this waste equipment at the time of disposal 
will help to conserve natural resources and ensure that it is recycled in a manner that 
protects human health and the environment. For more information on recycling an item 
marked with the WEEE symbol, please contact your local city office or your household 
waste disposal operation.

RoHS

COMPLIANT

Network

Ethernet connection (2) via screw terminals.

Recommended cabling

Ethernet: min. CAT 5 (STP) for 100 MBit 

Wiring standard

Ethernet 10/100 MBit

Summary of Contents for GAT Info 6100

Page 1: ...ompanies and depots System users are identified at the terminal via contactless RFID data carriers Radio Frequency Identification or NFC technology Information for user guidance is provided via a graphical monochrome display LCD The different models in the range see order information provide support for most popular RFID technologies Description Part No GAT Info 6100 B Information terminal for the...

Page 2: ...100 Power supply Network i Data carrier Dimensions 1 4 segment LED indicator 2 Monochrome display LCD 3 Function keys 4 Illuminated scan field 5 Device rear part 6 Device front part 93 mm 3 66 33 mm 1 3 24 mm 0 94 107 mm 4 2 2 3 4 5 6 1 Valid from July 1st 2016 Technical data subject to modification without notice DB_GAT INFO6100 EN_12 indd Part No 860380 Control elements 4 function keys RFID read...

Page 3: ... part to the wall using three screws Use the correct type of screws and dowels according to the wall material and ensure that the rear part is attached securely Complete the electrical connections according to the instructions on page 4 CAUTION The electrical connections must be made in a powerless state Attaching the device front part After installing the device rear part and completing the elect...

Page 4: ...harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that of which the re...

Reviews: