background image

6

www.gantner.com

Valid from June 10th, 2015 • Technical data subject to modification without notice! 
DB_GAT-ECOSide-Lock7000--EN_11.indd • Part No. 642832

Mounting on Glass Doors

3

3

1

7

5

50

 mm (1.9´´)

6 mm (0.24´´)

94 mm (3.7´´)

Loc

ker door (glass)

74 mm (2.91´´)

17 mm

 (0.67´´)

14.6 mm (0.57´´)

11 mm

 (0.43´´)

4

9.4 mm (1.94´´)

3

8.6 mm (1.52´´)

2

12

12

7

2

Loc

ker wall

17.6 mm (0.69´´)

16.4 mm (0.64´´)

1

3

3

3

3

Installation procedure
Note:

  Before installing all locks in a new locker system, a test installation 

of at least one lock and a final function check must be performed. 
Only once the functional testing is successfully completed may the 
remaining locks be installed in the same way.

1.  Drill 3 holes (3) for the GAT ECO.Side Lock 7000 into the locker wall. 
2.  Insert the batteries into the GAT ECO.Side Lock 7000 (see page 7).
3.  Mount the GAT ECO.Side Lock 7000 with 3 screws (3) on the inside 

locker wall.

Attention:

  Use the correct screws according to the type of locker 

material, max. Ø 4 mm (0.16´´). The maximum allowed 
tightening torque of the screws is 2 Nm (1.47 lb-ft).

4.  Use adhesive to attach the GAT NET.Lock BoltSet 7300 in the correct 

position to the inside of the locker door. Ensure the bolt set and metal 
support are screwed together before applying adhesive. GANTNER 
Electronic GmbH has successfully tested the following adhesives:

For transparent glass doors:

 

Conloc UV 680 from EGO. Only suitable for transparent glass doors 
without color-coating as this adhesive requires exposure to UV light 
(i.e., daylight) to cure.

 

For non-transparent glass doors:

 

Conloc UV 683 and Conloc Aktivator 953 from EGO. This combination 
does not require UV light to cure and is also suitable for opaque glass 
doors (e.g., with painted or color-coated tint treatment).

Attention:

  If comparable adhesives are to be used, test to ensure the 

adhesive meets the strength requirements. Always follow 
the adhesive manufacturer’s instructions. 

5.  A label (GANTNER standard design or custom design) can be 

attached to the locker front. If a custom label design is used, ensure 
that a transparent field for the LED light is included in the label design.

6.  Test the locker door to confirm that it can close easily and the door 

shackle inserts correctly into the GAT ECO.Side Lock 7000.

1.  GAT ECO.Side Lock 7000
2.  GAT NET.Lock Bolt Set 7300
3.  3 x mounting screws for the 
  GAT ECO.Side Lock 7000
5.  Door contact
7.  LED position
12. Metal support for glass door (included 

in the GAT NET.Lock BoltSet 7300)

Installation requirements for GAT ECO.Side Lock 7000 and bolt set

Please pay particular attention to the following points:
-  When the locker door is pressed shut, ensure there is no gap between 

the bolt set (2) and the front of the GAT ECO.Side Lock 7000. Ideally 
the bolt set should touch the front of the lock.

-  The front side of the bolt set and the GAT ECO.Side Lock 7000 must be 

aligned parallel to each other.

Summary of Contents for GAT ECO.Side Lock 7000

Page 1: ...of data carrier media such as chip cards chip bands and key tags are available The GAT ECO Side Lock 7000 is suitable for any kind of locker material wood HPL glass steel sheet and fully synthetic ma...

Page 2: ...100 0 mm 3 94 50 0 mm 1 97 94 0 mm 3 7 6 0 mm 0 24 125 2 mm 4 93 91 0 mm 3 58 17 0 mm 0 67 7 6 Top View Side View Front View 8 5 mm 0 33 2 2 2 40 3 mm 1 58 88 1 mm 3 47 1 4 4 5 4 1 25 0 mm 0 98 100 0...

Page 3: ...open close state of the door It is important that this contact remains clean and undamaged to ensure the correct functionality of the GAT ECO Side Lock 7000 Door width The minimum allowed door width m...

Page 4: ...cker door Front view without label carrier Locker door Front view with label carrier 15 1 mm 0 59 32 6 mm 1 28 Locker wall F Locker wall 3 3 17 4 mm 0 68 3 3 3 3 9 8 9 LED 6 8 6 LED position Cut out o...

Page 5: ...and a final function check must be performed Only once the functional testing is successfully completed may the remaining locks be installed in the same way 1 Drill 3 holes 3 for the GAT ECO Side Lock...

Page 6: ...s doors Conloc UV 680 from EGO Only suitable for transparent glass doors without color coating as this adhesive requires exposure to UV light i e daylight to cure For non transparent glass doors Conlo...

Page 7: ...nding material must not be disposed of with normal household waste Instead such marked waste equipment must be disposed of by handing it over to a designated electronic waste recycling facility Separa...