GAT Access 6100 Terminal Series
General Information
16
HB_GAT-ACCESS6100--EN_14
www.gantner.com
The
GAT TimeAxx 6150
is an elegant terminal for public baths, fitness studios and other leisure facilities where the
duration of use of services must be regulated. When used as a shower terminal, the terminal is installed directly in
the shower cubicle (see mounting instructions) and, via a digital output, controls an electro-valve that activates or
deactivates the shower. The remaining time is continuously shown to the user on a large graphical display, which
helps to reduce overall water consumption.
This device has the same electrical hardware as the other GAT Access 6100 terminals but uses a waterproof housing
for flush or surface mounting in shower areas. The terminal also has a display and LED signals, but no mechanical
buttons for user input.
1 ... Four-segment LED display
2 ... Monochrome display (LCD)
3 ... Illuminated, round scan field
4 ... Front frame
5 ... Device front part (below
the front frame)
6 ... Device rear part
Figure 2.5 - GAT TimeAxx 6150
2.3
Standard Operation
When a visitor of the leisure facility holds their data carrier next to the illuminated round RFID scan field, the GAT
Access 6100 reads the information on the data carrier and sends the data over the network (Ethernet) to a server for
evaluation.
The visitor’s authorization is checked and a response returned to the GAT Access 6100. When access is
granted, the GAT Access 6100 activates a corresponding relay output that opens the connected turnstile or gate for a
certain time period.
Visitors using the GAT Access 6100 F BIO must also scan their fingerprints (if this is activated) for additional
verification. The terminal compares the scanned fingerprint of a visitor with the data stored on the
visitor’s data carrier
and grants access only when the visitor is authorized and the fingerprint data matches.
Different settings for the GAT Access 6xxx, e.g., the access time of a turnstile/gate or the text displayed on the
terminal, can be defined via the configuration settings in GAT Config Manager. See "5.4. Configuration Settings" for
more information on configuring the terminals.
The GAT TimeAxx 6150 operates differently to the description above. After user identification, the terminal
activates the external application (e.g., opens the shower valve) and starts a countdown timer. The user can
pause the countdown and restart as required. After a configurable time the terminal deactivates the application.
Summary of Contents for GAT ACCESS 6100
Page 10: ...GAT Access 6100 Terminal Series Table of Contents 10 HB_GAT ACCESS6100 EN_14 www gantner com ...
Page 34: ...GAT Access 6100 Terminal Series Installation 34 HB_GAT ACCESS6100 EN_14 www gantner com ...
Page 80: ...GAT Access 6100 Terminal Series Operation 80 HB_GAT ACCESS6100 EN_14 www gantner com ...